LCD/Inverter Power Select
JP9 is used to select the power level of LVDS LCD inverter connector.
Chapter 2 Hardware Installation
Chapter 2
1
2
JP9
3
1-2 On:
+12V (default)
1
2
3
2-3 On:
+5V
18
Panel Power Select
JP8 is used to select the power supplied with the LCD panel.
Important:
Before powering-on the system, make sure that the power settings of JP8 match the
LCD panel's specification. Selecting the incorrect voltage will seriously damage the
LCD panel.
JP8
5
6
3
4
1
2
1-2 On: +12V
5
6
4
3
2
1
3-4 On: +5V
6
5
4
3
2
1
5-6 On: +3.3V
(default)
www.dfi .com