Diagnostic And Local I/O Cables - HP ProLiant BL40p Maintenance And Service Manual

Server blade
Hide thumbs Also See for ProLiant BL40p:
Table of Contents

Advertisement

Connectors, LEDs, and Switches
Table 4-2: System Components and Connectors
Item
14
15
16
17

Diagnostic and Local I/O Cables

Use either the diagnostic cable or the local I/O cable to perform some server blade
configuration and diagnostic procedures. Depending on the model, the server blade will have
either a diagnostic port or an I/O port. The I/O port only accepts the local I/O cable and the
diagnostic port only accepts the diagnostic cable. If the server blade has an I/O icon next to
the port on the front of the server blade, use the local I/O cable. If the port has no icon, use
the diagnostic cable.
Refer to Figure 4-4 and Table 4-3 to identify the I/O icon and the diagnostic and local I/O
cable connectors.
4-4
Component
Battery-Backed Write Cache Enabler
Ethernet passthrough board (connects
to chassis)
RJ-45 connectors
NIC I/O board
CAUTION: Disconnect the diagnostic cable or the Local I/O cable from the port when not in
use. The port and connector do not provide permanent connections.
CAUTION: Rear iLO connector performance degrades when the local I/O cable or the
diagnostic cable is installed, even when the iLO connector on the cable is not in use.
CAUTION: Always match the local I/O cable labeled with the I/O icon to the I/O port also
labeled with the I/O icon. The diagnostic cable and port have no labels. Mismatched cables
prevent proper connection.
continued
Item
31
32
33
34
HP ProLiant BL40p Server Blade Maintenance and Service Guide
Component
Processor fan connector
PPM slot 2
Processor socket 2
LED/power switch board with I/O
pass-through