HP ProLiant BL40p Maintenance And Service Manual page 20

Server blade
Hide thumbs Also See for ProLiant BL40p:
Table of Contents

Advertisement

Reverse steps 1 through 3 to install and power up a server blade. Server blades are set to
power up automatically upon insertion. If you have changed this setting, use the Power
On/Standby button or iLO Virtual Power Button feature to power up the server blade.
For more information about iLO, refer to the HP Integrated Lights-Out User Guide.
If you are not installing the server blade into either of the end bays, you will need to remove
the locking handle at the back of the server blade before installing it into the server blade
enclosure. To remove the locking handle:
1. Use a Torx-15 screwdriver to remove the three screws from the locking handle (1).
2. Remove the locking handle from the back of the server blade.
Figure 2-4: Removing the locking handle
HP ProLiant BL40p Server Blade Maintenance and Service Guide
CAUTION: Always populate server blade enclosure bays with either a server blade or server
blade blank. Operating the server blade enclosure without a server blade or server blade
blank results in improper airflow and improper cooling that can lead to thermal damage.
Removal and Replacement Procedures
2-7

Advertisement

Table of Contents
loading

Table of Contents