X. CABLE ADJUSTMENT
1. Loosen jam nut (A) from adapter (B) using 10mm wrench.
2. Using a 3/8-in wrench, turn adapter clockwise as shown to remove slop in cable. If the seat is not
holding the tilt angle securely, the cables may be adjusted too tight, and the adapter will need to be
turned counter-clockwise.
3. Once proper adjustment is obtained, re-tighten jam nut against adapter.
4. Repeat for opposite side of chair as necessary.
Y. CROSS BRACE
61
Adjustment
1.
Remove the four bolts (C) that attach the cross brace to the side frames.
2.
Move the cross brace to the desired location on the tabs (D).
3.
Replace and tighten the bolts.
NOTE– Align the bolts through holes in the tabs that correspond on each side. Re-tighten bolts to 11.3 Nm
[100 in-lbs]. Cross braces have 2 inches of width growth.
Z. STRUT TUBE ASSEMBLY
NOTE– Strut tubes are installed on rigid chairs.
Width Adjustment
1.
Remove hardware (E) from all strut tubes.
2.
Slide the adjustable extension (F) to the desired width.
3.
Replace and tighten the saddle bolts in the strut tubes.
NOTE– Strut tubes have 2-in width adjustment available. Size changes may require a larger seat insert and
footplates. Call your Sunrise Medical authorized dealer for details. Use a torque setting of 11.3
Nm [100 in-lbs] when making this adjustment.