Demo application
8.2 Creating a custom application
Figure 8-1
The version number of the demo application is shown at the bottom right in the application.
2. Use the option buttons to select the interface via which the reader is operated ("USB" / "RS232
COM").
3. Click the "Start" button to set up the connection to the reader and start the selected action.
4. To clear the display area, click on the "Clear" button.
5. Click the "Stop" button to disconnect the reader.
8.2

Creating a custom application

You can create custom applications for operation via USB or RS232 interface. The creation of
some sample applications is described below.
72
 
Read/Write
Manual reading/writing of the transponder data depending on the selected
(man.)
parameters.
 
Configcard
Transferring the configuration from the configuration card in the antenna field
to the reader.
 
Reset2Factory
Resetting the reader to factory settings and deleting user-specific data.
 
Reverse UID
Reversing the byte sequence when the serial number is output.
Input boxes
 
VHL file number Input box for the ID of the VHL function
Default = 255; if no configuration has been transferred to the reader. The cor‐
responding VHL ID must be selected for a specific configuration.
 
address
Input box for the start address as of which the transponder data is to be read or
written.
 
length
Input box for the data length of the transponder data to be read/written.
Example view of reading a serial number
Option buttons
Read SerNr
Read Data (auto)
Read/Write (man.)
Configcard
Description
Read the serial number and the card type. The data is output in the top
display area.
Automatic, periodic reading of the transponder data depending on
the card-type specific configuration. The data is output in the bottom
display area.
Requirement: Autoread configuration is stored on the reader.
Manual reading/writing of transponder data depending on the selec‐
ted VHL function ("VHL file number"), as well as the start address and
the data length ("address" and "length").
The read or write operation is initiated with the "Read Data" or "Write
Data" buttons.
The transponder data to be written or read are edited or output in the
bottom input/display area.
Transferring the configuration from the configuration card in the an‐
tenna field to the reader. Note that the connection is terminated after
the transfer ("Stop") and must be reestablished ("Start").
Operating Instructions, 05/2023, C79000-G8976-C432-10