Vhl_Is_Selected - Siemens SIMATIC RF1000 Operating Instructions Manual

Hide thumbs Also See for SIMATIC RF1000:
Table of Contents

Advertisement

Byte
5
6
7
8
9
Table 7-37
Byte
0
1
2
3
4
5
6
7.3.2.8

vhl_is_selected

Max. reader response time: 3 s
Table 7-38
Byte
0
1
2
3 ... 4
5
Table 7-39
Byte
0
1
2
3 ... 4
5
SIMATIC RF1000
Operating Instructions, 05/2023, C79000-G8976-C432-10
7.3 Programming via the RS232 interface (using the Freeport protocol)
Value
Description
0x11
Serial number of the card, depending on card type
0x22
0x33
0x44
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram with errors
Value
Description
0x8C
Without checksum
0x9C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x01
CmdCode of the command to be called.
0x01
Parameter length (1 byte)
0x00
0x02
CARD_NOT_SELECTED_ERR
0x9F
Optional checksum (when the value "0x9C" is set in byte 0)
Request telegram
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x04
CmdCode of the command to be called.
0x00
Parameter length (0 bytes)
0x08
Optional checksum (when the value "0x1C" is set in byte 0)
Response telegram without errors
Value
Description
0x0C
Without checksum
0x1C
With checksum
0x01
DevCode of the command set containing the command to be called.
0x04
CmdCode of the command to be called.
0x00
Parameter length (0 bytes)
0x08
Optional checksum (when the value "0x1C" is set in byte 0)
Programming