Maintenance and care
Gripping width cannot / cannot be
adjusted correctly
7.3

Repairs

Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by an expert.
7.4

Safety procedures

It is the contractor's responsibility to ensure that the device is checked by an expert in periods of
max. 1 year and all recognized errors are removed (→ see DGUV regulation 1-54 and DGUV norm 100-500).
The corresponding legal regulations and the regulations of the declaration of conformity must be
observed!
The expert inspection can also be done by the manufacturer Probst GmbH.
Contact us at:
service@probst-handling.de
We recommend affixing the inspection sticker "„Sachkundigenprüfung / Expert inspection" in a clearly
visible place (order no.: 2904.0056+Tüv sticker with year number) after the inspection has been done.
The check by an expert must be proved!
Device
Year
54500008
22 / 23
Adjustment spindle for adjusting
the gripping width clamps
Foreign matter on the adjusting
spindle
Dust or dirt on the adjustment
spindle
Lack of lubrication of the adjusting
spindle
Date
V4
Move the locking tab to the
release position, see chapter
"Adjustment".
Check for possible foreign bodies
on the adjustment spindle and
remove them
Clean the adjustment spindle with
high pressure cleaner
Lubricate adjustment spindle
Expert