Figure 7-33 Control Termina ons on Variable Frequency Drive
V Series
Max
Washer
Spin
Model
Speed
T-300, T-400,
60 G
T-600, T-900,
80 G
T-1200
100 G
60 G
T-350, T-450,
100 G
T-750
140 G
200 G
100 G
T-650, T-1450
140 G
200 G
Table 7-2 Spin Speed Adjustment Jumper Loca ons

7.1.14 Injec on Source Connec ons

The washer control may be programmed to send six 24V output signals for a chemical injection
system of up to four chemical sources. The signals are not intended as a power source and
must be limited to less than 100 milliamps of current. There is a separate terminal block for
connection of the external injection signals. For the injection sources, program codes 0 through
6 and their respective terminal block connections are as shown in the figure below.
8514-301-001 REV PR
Jumper Terminal Locations on Variable Frequency Drive (VFD)
MI1 MI2 MI3 MI4 MI5 MI6
X
Default Setting (No Jumper Required)
X
X
Default Setting (No Jumper Required)
REMOVE Brown Jumper Between MI5/M01
Default Setting (No Jumper Required)
DCM
DCM
(Left)
(Right) 24V
X
X
X
ACM
AVI
ACI 10V M01
X
X
X
X
X
X