Unit Status View - Gree XK75 Owner's Manual

Wired controller
Table of Contents

Advertisement

When level 3 is selected, the adjusting range of accumulating operating time is
100~1000 hours, with 100 hours in each increase or decrease.
This function is used to remind you to clean the filter when the unit's own operating
time is reach your setting.
Whenever you turn off this function, the unit's operating time will be zero clearing.
3.7.12 Fahrenheit Temperature Setting
After entering user function page, press "∧" or "∨" button to select Fahrenheit
temperature function and press "<" or ">" button to turn on or turn off this function with
auto saving. After closing this function, Celsius temperature will be displayed.
3.7.13 Fixed-angle Swing Mode Setting
After entering user function page, press "∧" or "∨" button to select lock swing
function option and press "<" or ">" button to turn on or turn off this function with auto
saving.
Note: If fixed-angle swing function is not available for the connected unit, this
function will be cancelled automatically after setting.
3.7.14 Low-temperature Drying Function Setting
After entering user function page, press "∧" or "∨" button to select
low-temperature drying function and press "<" or ">" button to turn on or turn off this
function with auto saving.
Note:
① .
This function is only available in dry mode.
② .
When low-temperature drying function is on, the displayed set temperature in
dry mode is 12℃(54℉). This function will be off automatically after readjusting
set temperature.

3.8 Unit Status View

Press MENU button to enter the menu and select the function symbol to be viewed.
Then press MENU button to enter view function page. Press "∧" or "∨" button to select
status view function. Press MENU button to enter unit status view page. Press BACK
button to return to the last page. Please refer to Fig. 9.
The following statuses can be viewed: if defrosting is operating; if auxiliary heating
is operating; residual time of filter cleaning reminder; indoor ambient temperature;
outdoor ambient temperature.