Personal Protective Equipment; Transport; Device Description; Device Overview - GARANT HCT User Manual

Digitale messuhr
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17
GARANT Digital dial indicator HCT
de
Open the casing only at the battery cover to change the batteries.
Do not make any unauthorised modifications.
en
3.4.

PERSONAL PROTECTIVE EQUIPMENT

Comply with the national and regional regulations for safety and accident prevention. Select and provide protective work
wear such as safety shoes and safety gloves appropriate for the risks associated with the intended activities.
bg
4.

Transport

Transport in the original packaging at temperatures between -10°C and +60°C. Prevent from falling.
da
5.

Device description

Digital dial indicator for measuring lengths and differences in lengths and for taking reference, flatness, positional and run-
fi
out measurements.
Digital display with additional scale.
External data transmission via proximity cable (USB), Power-RS (power USB) or via BT.
fr
External data transmission via proximity cable (USB) or via Power-RS (power USB).
6.

Device overview

it
6.1.

DIAL INDICATOR

A
hr
1
MENU button
2
SET button
lt
3
DATA button
4
Button (left)
nl
5
Button (right)
6.2.

BUTTON FUNCTIONS

no
MENU
MENU
SET
SET
pl
DATA
pt
Left /
ro
right
ru
6.3.

DISPLAY OVERVIEW

B
sv
11
Low battery
12
+ / - display
sk
13
Keyboard lock
14
Display of 6 digits
sl
15
Hold the measurement value
16
Data transmission
es
17
Unit of measurement mm / INCH
18
Preset mode
cs
19
Scale
20
Lower limit value undershot
hu
20
Switches between the functions of the two function levels on the dial indicator. The first level con-
tains basic functions; the second contains advanced functions.
Confirms a selection.
Switches off the dial indicator.
Moves to the next step within a function.
Switches between the BT modes OFF / HID / APP.
Transfers measurement values.
Define the display area for the scale.
Reduce/increase the numerical value step by step.
Activate the setting for the nominal value and tolerance limits.
6
Clamping shank Ø8 or 3/8"
7
Ball contact point Ø2/M2.5 or 4-48-UNF
8
Lifting cap
9
Socket for proximity cable
10
Battery insert or power cable socket
21
Upper limit value exceeded
22
Tolerance indicator
23
Lower limit value of scale
24
Upper limit value of scale
25
Unit and scale graduation
26
Tolerance mode
27
MIN/MAX/DELTA mode
28
Multiplier
29
BT connection
30
Symmetrical tolerances

Advertisement

Table of Contents
loading

This manual is also suitable for:

434342