H Maintenance Messages; I Comfort Protection Mode; J Fault Codes - Vaillant uniTOWER plus Operating Instructions Manual

Table of Contents

Advertisement

H
Maintenance messages
Code
Meaning
M.23
Status external current anode
M.32
Building circuit: Waterpress. Low
M.200
Building circuit : Brine pressure
low
M.201
Sensor fault: Cylinder temperature
M.202
Sensor fault: System temperature
M.203
Connection fault: Disp. not recog-
nised
I
Comfort protection mode
Code
Meaning
200
Sensor fault: Temp. air inlet
J
Fault codes
Code
Meaning
F.022
Building circuit: Water press. too
low
F.042
Fault: Coding resistor
F.073
Sensor fault: Building circ. water
pressure
F.094
Fault: Vortex
F.103
Fault: Spare part ident.
F.514
Sensor fault: Compr. inlet temp.
56
Cause
External current anode not recog-
nised
Pressure loss in the building circuit
due to leakages or air pockets
Building circuit pressure sensor is
defective
Pressure loss in the building circuit
due to leakages or air pockets
Building circuit pressure sensor is
defective
Cylinder temperature sensor defect-
ive
System temperature sensor defective
Display defective
Display not connected
Description
Still possible to operate with existing,
functional outdoor temperature sensor
Cause
Pressure loss in the building circuit
due to leakages or air pockets
Building circuit pressure sensor
defective
Coding resistor damaged or not set
The sensor is not connected or the
sensor input has short-circuited
Volume flow sensor not connected or
sensor input has short-circuited
Incorrect control PCB installed on
the outdoor unit
The sensor is not connected or the
sensor input has short-circuited
Installation and maintenance instructions 0020291525_04
Remedy
If required, check for a cable break
Check the building circuit for leaks,
top up with heating water and purge
Check the plug contact on the PCB
and on the wiring harness; check
that the pressure sensor is working
correctly and, if required, replace the
pressure sensor
Check the building circuit for leaks,
top up with heating water and purge
Check the plug contact on the PCB
and on the wiring harness; check
that the pressure sensor is working
correctly and, if required, replace the
pressure sensor
Check the plug contact on the PCB
and on the wiring harness; check
that the sensor is working correctly
and, if required, replace the sensor
Check the plug contact on the PCB
and on the wiring harness; check
that the sensor is working correctly
and, if required, replace the sensor
Check the quality of the plug contact
on the PCB and on the wiring har-
ness
Replace the display, if required
Remedy
Replace the air inlet sensor
Remedy
Check the building circuit for leaks
Top up with water, purge
Check the quality of the plug contact
on the PCB and on the wiring har-
ness
Check that the pressure sensor is
working correctly
Replace the pressure sensor
Check that the coding resistor is
positioned correctly and, if required,
replace it.
Check and, if required, replace the
sensor
Replace the wiring harness
Check and, if required, replace the
sensor
Replace the wiring harness
Installing the correct PCB
Check and, if required, replace the
sensor
Replace the wiring harness