  • Page 1 AL175UL Access Control Power Supply/Charger Installation Guide Altronix Corp. 140 58th St. Brooklyn, NY More than just power. Rev. 052019 Installing Company: _______________ Service Rep. Name: __________________________________ Address: _____________________________________________ Phone #: __________________...
  • Page 2 Alarm = 1.25A Installation Instructions: The AL175UL should be installed in accordance with article 760 of The National Electrical Code or NFPA 72 as well as all applicable Local Codes. See Terminal Identification Chart on page 4 for a description of each terminal function.
  • Page 3 Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 3. Set the AL175UL to the desired DC output voltage by setting switch SW1 to the appropriate position (Power Supply Output Specification Table).
  • Page 4 Connects to the normally closed outputs of an access control or fire alarm relay. TRG1 & TRG2 These terminals control [LOCK +], and [STRIKE +], as well as AL175UL output relay contacts [NC, NO, C]. Provides DC output voltage when [TRG1] and [TRG2] are shorted together and are LOCK + typically used to power Mag Locks.
  • Page 5 Fig. 1 - AL175UL SW1 ON - 24V OFF - 12V TRG1 TRG2 AL175ULB + BAT -- LOCK + STRIKE + COM -- AUX + FACP AUX -- Switched Constant output Stand-by DC output (Not affected Battery (trigger control) by trigger)
  • Page 6 TRG2 TRG1 FACP Fig. 3 Typical dual mag lock installation with fire alarm tie-in using trigger controlled outputs: ACCESS CONTROL DEVICE MAG LOCK LOCK + STRIKE + MAG LOCK COM – FACP TRG2 TRG1 - 6 - AL175UL Installation Guide...
  • Page 7 Fig. 5 Latching fire alarm tie-in with manual reset: ACCESS CONTROL DEVICE LOCK + STRIKE + MAG LOCK COM – FACP TRG2 TRG1 NO RESET SWITCH Fig. 6 Multiple AL175UL(X) power supply connections: TRG1 TRG2 AL175UL Installation Guide - 7 -...
  • Page 8 (25.4mm) 5.25” (133.35mm) 1” 1” (25.4mm) (25.4mm) Altronix is not responsible for any typographical errors. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIAL175UL F29U...