Models Include:
AL175220
- Enclosure Dimensions:
8.5" x 7.5" x 3.5"
(215.9mm x 190.5mm x 88.9mm).
- Accommodates one (1)
12VDC/4AH battery.
Rev. 011316
AL175X220
- Enclosure Dimensions:
13.5" x 13" x 3.25"
(342.9mm x 330.2mm x 82.6mm).
- Accommodates up to two (2)
12VDC/7AH Batteries.
More than just power.
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AL175220 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix AL175220 Series

  • Page 1 AL175220 Series Access Control Power Supply/Chargers Models Include: AL175220 AL175X220 - Enclosure Dimensions: - Enclosure Dimensions: 8.5” x 7.5” x 3.5” 13.5” x 13” x 3.25” (215.9mm x 190.5mm x 88.9mm). (342.9mm x 330.2mm x 82.6mm). - Accommodates one (1) - Accommodates up to two (2) 12VDC/4AH battery.
  • Page 2 Overview: Altronix AL175220 and AL175X220 are power-limited power supply/chargers that converts 220VAC (working range 198VAC - 256VAC), 50/60Hz input into two individually PTC protected auto-resettable 12VDC or 24VDC outputs (see specifications). They are intended for use in Access Control applications and applications requir- ing an interface with the Fire Alarm Control Panels.
  • Page 3 + BAT – Stand-by battery connections. AC FAIL Indicates loss of AC, e.g connect audible device or alarm panel. NC, C, NO Relay normally energized when AC power is present. Contact rating 1A @ 28VDC. AL175220 Series - 3 -...
  • Page 4 STRIKE + COM -- AUX + FACP AUX -- + BAT -- Input 220VAC 50/60Hz, 0.3A Constant output Stand-by Switched XFMR Black Lead (Not affected DC output Battery White Lead by trigger) (optional) (trigger control) - 4 - AL175220 Series...
  • Page 5 AUX -- TRG2 TRG1 FACP Fig. 3 Typical dual mag lock installation with fire alarm tie-in using trigger controlled outputs: ACCESS CONTROL DEVICE MAG LOCK LOCK + STRIKE + MAG LOCK COM -- FACP TRG2 TRG1 AL175220 Series - 5 -...
  • Page 6 Fig. 5 Latching fire alarm tie-in with manual reset: ACCESS CONTROL DEVICE LOCK + STRIKE + MAG LOCK COM -- FACP TRG2 TRG1 NO RESET SWITCH Fig. 6 Multiple AL175220 (AL175X220) power supply connections: TRG1 TRG2 - 6 - AL175220 Series...
  • Page 7 (15.24mm) (31.75mm) (153.67mm) 1.125” 1.125” (28.575mm) (28.575mm) 2” (50.8mm) 2” (50.8mm) 8.125” (206.375mm) 1” 1” (25.4mm) (25.4mm) 6.05” 0.6” 0.6” 1.25” (153.67mm) (15.24mm) (15.24mm) (31.75mm) 3.5” (88.9mm) 1” (25.4mm) 1” 5.25” 1” (25.4mm) (133.35mm) (25.4mm) AL175220 Series - 7 -...
  • Page 8 (267mm) (25mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. MEMBER IIAL175220 Series C21R...