Page 1
HOME OWNERS INSTRUCTIONS & OPERATING MANUAL FLAMONIK ENCHANT & RAPTURE ELECTRIC FIRE Part No.: B-1004535 & B-1004536 Model No.: CFECR0RE-ERP & CFECE0RE-ERP Packing Check list Package 1 1 off Electric fire 1 off Remote control handset* 1 off Instructions manual...
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER IMPORTANT INSTRUCTIONS PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION AND/OR USE OF THIS ELECTRIC FIRE AND RETAIN FOR FUTURE REFERENCE. WHEN USING ELECTRICAL APPLIANCE, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSONS, INCLUDING THE FOLLOWING IMPORTANT SAFETY ADVICE.
Page 3
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER IMPORTANT INSTRUCTIONS DO NOT cover the heater. The meaning of figure is “WARNING! DO NOT COVER”. This is to avoid over-heating of the product. DO NOT leave the heater unattended while it is in use. Always turn the appliance to the OFF position and unplug it from the electrical outlet when not in use.
Page 4
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER PRODUCT TECHNICAL DATA SHEET Supplier Name / Trademark CELSI Supplier Model Identifier B-1004535 Flamonik Rapture 27” B-1004536 Flamonik Enchant 36” Voltage 230v AC 50HZ Fuse 13 Amp Nominal Heat Output (Measured) 1.5 kW Minimum Heat Output (Indicative) 0.75 kW...
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER INSTALLATION PREPARATION WANING! DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT AND TO REPLACE ANY PART OF THE ELECTRICAL SYSTEM IF NECESSARY. · Open the packaging carefully and remove the foam. ·...
Page 6
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER LOCATING YOUR ELECTRIC FIREPLACE/HEATER This appliance may be installed virtually anywhere in your home. However, when choosing a location please ensure that the general instructions are followed. For best results, install out of direct sunlight. Make sure that the plug or fused spur is accessible after the electric fire is fitted. Before connecting the appliance make sure that its rating corresponds to that of the mains supply and the fuse is the correct rating.
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER INSTALLATION INSTRUCTIONS Step 1: Using a screwdriver loosen the two screws that secure the wall mounting bracket to the top of the appliance and remove the wall mounting bracket as shown below (Figure 1). Figure 1 Step 2: Choose a solid and plain wall. Position the mounting bracket where the appliance is to be installed on the wall and ensure that the bracket is level.
Page 8
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER Step 4: Fix the mounting bracket using the four screws supplied (Figure 4). Step 5: Hang the appliance on the hooks at the bottom of the bracket and push the top of the appliance into the mounting bracket. Now fix the appliance to the mounting bracket by refitting the two M4×8 screws which were removed in step 1.
Page 9
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER OPERATING INSTRUCTIONS CAUTION! THE UNIT’S POWER CORD MUST BE CONNECTED TO A PROPERLY EARTHED AND PROTECTED 230V OUTLET. ALWAYS USE EARTH FAULT PROTECTION WHERE REQUIRED BY THE ELECTRICAL CODE. This appliance can be operated by both a remote control and a manual keypad on the product. Once the unit has been properly connected to an earthed electrical socket-outlet ensure the manual On/Off switch, located on the right hand side of the appliance, is in the ‘ON’...
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER The next button is the (2) Flame Control button. Pressing the button once turns on the flame and fuelbed lights only. Further presses of the button will cycle through all the available colours as listed below and eventually back to OFF. BUTTON PRESS Flame State Fuel bed Colour...
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER Remote Control Button Function Remove the battery cover on the back of the handset by sliding downwards and insert 2 x AAA batteries ensuring that the batteries are fitted correctly. Refit the battery cover. Ensure that the ON / OFF Power Switch on the fire is in the ON position. OPERATING INSTRUCTION WITH REMOTE CONTROL Point the remote control handset directly towards the fire and press the appropriate button to operate the fire.
Page 12
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER HEAT When the heat icon is selected and blinking, pressing the buttons within 5 seconds will adjust the heat output between Low Heat (0.75kW) , High Heat (1.5kW) , and OFF (OF) options. If no buttons are pressed within 5 seconds the heat icon will stop blinking and the heat output will be set to memory.
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER IMPORTANT This appliance is fitted with an automatic thermal cut-out safety feature to reduce the risk of damage to the appliance in the event of overheating e.g. when covered. If the thermal cut out has detected an abnormal temperature rise within the appliance it will beep and shut off the fan heater preventing it from restarting.
WALL-MOUNTED ELECTRIC FIREPLACE/HEATER ENVIRONMENT Do not dispose of electrical appliances as unsorted municipal waste. Use separate collection facilities. Contact your local government for information regarding the collection services available in your local area. If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain, thus damaging your health and wellbeing.