U601 Initializing Permanent Data - Olivetti FAX System M-New Service Manual

Option copier
Table of Contents

Advertisement

Maintenance
item No.
Initializing permanent data
U601
Description
Initializes software switches on the fax control PWB according to the destination and OEM.
Purpose
To initialize the fax control PWB without changing user registration data.
Method
1. Press the start key.
2. Press [Execute]. The screen for entering the destination code and OEM code is displayed.
The port that is addressed by U698 is displayed when the optional dual FAX is installed.
3. Select [Country Code] and enter a destination code using the numeric keys (refer to the destination
code list on page 1-3-6 for the destination code).
4. Press the start key.
There is no operation necessary on this screen.
The destination code and the OEM code are displayed with the values currently set.
An asterisk (*) is displayed if U698 is set to [ALL] and settings for ports 1 and 2 are not identical.
In this case, initialization is not possible.
5. Press the start key. Data initialization starts. To cancel data initialization, press the back key.
6. After data initialization, the entered destination, OEM codes and ROM version are displayed. A ROM
version displays three kinds, application, boot, and IPL.
When U698 is set to [ALL], the ROM version for port 1 is primarily displayed.
MAINTENANCE MODE
MAINTENANCE MODE ACTIVE.
Initialize: Keep Data
Country Code
OEM Code
MAINTENANCE MODE
MAINTENANCE MODE ACTIVE.
Initialize: Keep Data
Country Code
OEM Code
APL
BOOT
IPL
Y108810-2
XXX
YYY
XXX
YYY
****************
****************
****************
Service Manual
Description
U601
U601
3KH-2
1-3-7