Gas and Electric Supply Zone
Model
36" (913mm)
48" (1219mm)
NOTICE:
--
If not already present, install gas shut-off valve in an
easily accessible location.
--
Make sure all users know where and how to shut off
the gas supply to the range.
--
Any opening in the wall behind the appliance and any
opening in the floor under the appliance must be
sealed.
The dual fuel ranges may be connected to the power
supply with a range supply cord kit or by hard-wiring to the
power supply. It is the responsibility of the installer to
provide the proper wiring components (cord or conduit and
wires) and complete the electrical connection as dictated
by local codes and ordinances, and/or the National Electric
Code. The units must be properly grounded. Refer to
"Step 7: Electrical Requirements, Connection & Grounding"
on page 16 for details.
A
9
" (232mm)
23 " (587mm)
10" (254mm)
A
B
B
C
7 " (187mm)
7 " (187mm)
7" (178mm)
7" (587mm)
3" (76mm)
C
36" Model (913mm)
48" Model (1219mm)
The range must be connected only to the type of gas
for which it is certified. If the range is to be connected to
propane gas, ensure that the propane gas supply tank is
equipped with its own high pressure regulator in addition to
the pressure regulator supplied with the range (see
"Step 6: Gas Requirements and Hookup" on page 14).
NOTE:
The range is designed for nearly-flush installation to the
back wall. For a successful installation, it may be
necessary to reposition the gas supply line and electrical
cord as the range is pushed back to its final position.
--
SUGGESTION: This may be accomplished by carefully
pulling on a rope or twine looped around the gas or
electrical supply line as the range is pushed back into
its final installed position.
D
9 " (232mm)
7
" (200mm)
2"
(51m)
D
Figure 3: Gas & Electrical Supply Locations