Operation - Toyotomi Toyostove Laser 300 Installation And Operation Instruction Manual

Laser clean heating system/vented heater
Hide thumbs Also See for Toyostove Laser 300:
Table of Contents

Advertisement

Laser 300_Type A_US.qxd 15.3.26 16:11 ページ 10
3) Setting of a day of the week
"dAy" sign is shown on the display and all of days of the week will blink.
Press the "▲MIN." button or the "▼HOUR" button to set a day of the week. A day of the week will blink. (Initial
setting is "SUN".) The other days of the week will go off. Select a day of the week by using the "▲MIN." or the
"▼HOUR" button. When pressing the "▲MIN." button, the sign will change as follows.
"SUN" ➞ "MON" ➞ "TUE" ➞ "WED" ➞ "THU" ➞ "FRI" ➞ "SAT"
When pressing the "▲MIN." button at the position of "SAT", you can hear a beep sound and "SAT" is not
changed any more. When pressing the "▼HOUR" button, the sign will change as follows.
"SAT" ➞ "FRI" ➞ "THU" ➞ "WED" ➞ "TUE" ➞ "MON" ➞ "SUN"
When pressing the "▼HOUR" button at the position of "SUN", you can hear a beep sound and "SUN" is not
changed any more.
Press the "SET" button to complete the setting of the days of the week. The current time and a day of the week
will show on the display.
Note: If the ON/OFF switch is pressed during setting of the current time and a day of the week after setting the
time and a day of the week, the set mode of the current time will terminate and the operation will start. If a
day of the week is set, the time is fixed. If a day of the week is not set, the contents of the setting are
deleted.
MANUAL OPERATION
Operation of the heater is under the direct control of the user. Heat output will, however, be automatically
adjusted in accordance with the room temperature registered by the temperature sensor.
1. Turn Heater ON
A. Press ON/OFF button to "ON" position. The current room temperature and the set temperature will be
shown on the button digital indicator. ON lamp will start to flash and then blower motor and ignition will
start. This lamp will continue to flash during the preheating time.
B. After approx. 1.5 – 4 minutes ignition will take place. (*) After ignition, ON lamp will change flashing to
continuous. Circulation fan will turn on after approx. 2 minutes.
Note: (*) Pre -heating depends on the room temperature.
Room temperature: below 34˚F
10

OPERATION

Approx.
4 minutes
34˚F - 61˚F
2 minutes
"
over 61˚F
1.5 minutes
"