Your Laser 300 is equipped with the following safety features. Please familiarize yourself with these features.
When your heater is extinguished due to a safety mechanism, be sure to identify and correct the problem.
1.
Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to
prevent fuel overflow. Error code will be displayed on the digital indicator.
2.
Fuel Strainer
Special strainer catches dirt or impurities present in the fuel before it is sent to the burner.
3.
Overheat Protector
Automatically stops all operations if heater inside cabinet reaches abnormally high temperature due to motor
malfunction or abnormal combustion, in order to prevent fire.
4.
Power Failure Recovery System
If power fails during heater operation, heater will automatically reignite and maintain the normal selected
temperature, when power resumes.
5.
Fully Vented System
Flue pipe system uses outside air for combustion and vents all combustion products to the outdoors.

SAFETY FEATURES

Circulation fan
Fuel pump
Red reset button
Fuel sump
Integral fuel
strainer (inside)
Blower motor
Fuel pipe
Heat shield plate
Overheat protector
Heat exchanger
Peep hole
Flame sensor
Burner ring
Igniter
Drip tray
Burner