Kohler 48RCLB/C Operation page 22

Residential/light commercial generator sets

Advertisement

Fault (RDC2)
Fault (OnCuer
Plus)
AC Sens Loss
AC Sensing
Lost
Warning
(1 sec.)
Shutdwn
(3 sec.)
Accy PwrOver
Accessory
Warning
Power Overload
ATS ComError
ATS
Warning
Communication
Error
ATS PhaseRot
ATS Phase
Warning
Rotation
Mismatch
Aux Input
Auxiliary Input
Shutdwn
Battery CrLo
Battery Voltage
Warning
Critically Low
Warning
Battery High
Battery Voltage
Warning
High Warning
Battery Low
Battery Voltage
Warning
Low Warning
Chk DateTime
Verify Date
Warning
Time Setting
Coolant Level
Coolant Level
Low Shutdwn
Low
Coolant Temp
Coolant
High Warning
Temperature
High
Crank Lost
Crank Sensor
Shutdown
Signal Lost
ECM warnings
ECM warnings
(any warnings
(any warnings
with ECM in the
with ECM in
fault name)
the fault name)
22
Section 2 Generator Set Operation
Condition
AC Sensing Lost. In Auto mode, generator
output AC sensing is lost. Detection begins 10
seconds after crank disconnect.
Warning: after 1 second if no output detected
after crank disconnect.
Shutdown: after 3 seconds if voltage was
present and then lost.
Accessory Power Overload. An over current
fault (short circuit) on the accessory controller
power output.
ATS Communication Error. Warning is
displayed if RXT interface connection is lost.
See Section 2.6.3.
ATS Phase Rotation Mismatch. Transfer
switch phase rotation does not match. ATS will
not transfer.
Auxiliary Input. An optional
customer-connected input is closed. (Digital
input from optional PIM.)
Engine starting battery voltage falls below 11
V for more than 10 seconds. Inhibited during
the engine crank cycle.
Clears when the battery voltage returns to an
acceptable level.
Engine starting battery voltage rises above
133% (16 V) of the battery voltage setting for
more than 10 seconds. Inhibited during the
engine crank cycle.
Clears when the battery voltage returns to an
acceptable level.
Engine starting battery voltage falls below the
battery voltage setting (typically 12.5 volts) for
more than 90 seconds when the engine is not
running. Inhibited during the engine crank
cycle.
Clears when the battery voltage returns to an
acceptable level.
The time and date have not been set on the
generator controller.
The coolant level switch input has been
activated.
Coolant temperature is too high.
Crankshaft Position Sensor (CPS) timeout
error occurred.
This group of faults includes a wide variety of
faults that originate from the engine ECM
and also contain ECM in the fault name.
Check
Contact an authorized dealer for
service.
Contact an authorized dealer for
service.
Contact an authorized dealer for
service.
Contact an authorized dealer for
service.
Check customer-supplied equipment.
Check the battery rating and
condition.
Check the battery charger operation.
Charge or replace the battery.
Check the battery rating and
condition.
Check the battery charger operation.
Check the battery rating and
condition.
Check the battery charger operation.
Charge or replace the battery.
Enter the date and time using the
RDC2 controller. See Section 3.5 and
Figure 3-16 for instructions.
Check coolant level.
Check radiator hoses for leaks.
Contact an authorized dealer for
service.
Check coolant level.
Check the enclosure vents for
obstructions.
Contact an authorized dealer for
service and provide the fault code.
Contact an authorized dealer for
service and provide the fault code.
Contact an authorized dealer for
service and provide the fault code.
TP-7102 9/21