Please contact the Dealer of our company if you need to adjust or replace the components.
1 Precautions during maintenance:
The components for replacement shall be produced completely by our company.
When replacing components of the truck, the components with the same safety
requirement with the original design shall be used.
The lubricating oil and hydraulic oil in use shall be recommended by our
company.
Places for maintenance:
The places for maintenance shall be appointed and can provide other
services such as hoisting and safety protection facility etc.
The places shall have level ground and good ventilation.
The places shall be equipped with fire-extinguishing devices.
Precautions before repair and maintenance:
2 Inspection and maintenance before the new truck put into operation
In order to follow the industry related regulations and ensure the absolute security to the truck in the
transportation, for new ex-factory truck, it is possible that there is no electrolyte inside storage battery
before the first use (except the inland sale).
The electrolyte of storage battery is prepared well before the truck leave the factory, and it is filled into the
Notice
All the repair work shall be carried out by professional personnel.
Notice
Notice
Notice
No smoking.
Arrange the self-protection work.
Wipeout the effusive oil in time.
Before adding lubricating oil, clean up the dirty oil or dust on the joint with brush
or cloth.
Except certain situation, turn off the key switch and pull off the power socket.
Lower down the fork arms to the lowest point when carrying out maintenance.
Ensure no goods on the truck when demounting the high pressure oil pipe.
Besides, the fork arms shall be descended to the lowest position, by this way,
the pressure of hydraulic system can be released.
For the reason that there are capacitors storing a little amount of electric energy
in circuit, so before contacting the binding post of the main circuit, discharge at
first.
Clean the electric section with compressed air, never flush with water.