For The User; 10 About The System; System Layout; User Interface - Daikin RXYSQ8TMY1B Installation And Operation Manual

System air conditioner
Hide thumbs Also See for RXYSQ8TMY1B:
Table of Contents

Advertisement

10 About the system

Q1LD
Leakage detection circuit (A1P)
Q1RP
Phase reversal detect circuit (A1P)
R1T
Thermistor (air)
R21T
Thermistor (discharge)
R3T
Thermistor (suction)
R4T
Thermistor (heat exchanger liquid pipe)
R5T
Thermistor (liquid pipe)
R6T
Thermistor (subcool heat exchanger)
R7T
Thermistor (heat exchanger de-icer)
R8T
Thermistor (M1C body)
R1
Resistor (current limiting) (A3P)
R24
Resistor (current sensor) (A4P)
R313
Resistor (current sensor) (A3P)
R865, R867
Resistor (A3P)
S1NPH
High pressure sensor
S1NPL
Low pressure sensor

For the user

10
About the system
The indoor unit part of VRV IV-S heat pump system can be used for
heating/cooling applications. The type of indoor unit which can be
used depends on the outdoor units series.
NOTICE
Do not use the system for other purposes. In order to avoid
any quality deterioration, do not use the unit for cooling
precision instruments, food, plants, animals or works of art.
NOTICE
For future modifications or expansions of your system:
A full overview of allowable combinations (for future
system extensions) is available in technical engineering
data and should be consulted. Contact your installer to
receive more information and professional advice.
INFORMATION
▪ Combination of VRV DX and RA DX indoor units is not
allowed.
▪ Combination of RA  DX and AHU indoor units is not
allowed.
▪ Combination of RA DX and aircurtain indoor units is not
allowed.
10.1

System layout

a
b
c
c
f
d
d
a
VRV IV-S Heat pump outdoor unit
b
Refrigerant piping
c
VRV direct expansion (DX) indoor unit
d
User interface (dedicated depending on indoor unit type)
Installation and operation manual
34
e
e
f
g
g
S1PH
High pressure switch
SEG1~SEG3 7-segment display (A1P)
T1A
Current sensor
V1R
Power module (A3P) (A4P) (A5P)
V2R
Power module (A3P)
X1A, X2A
Connector (M1F)
X3A, X4A
Connector (M2F)
X1M
Terminal strip (power supply)
X1M
Terminal strip (control) (A1P)
Y1E
Electronic expansion valve (main)
Y2E
Electronic expansion valve (subcool heat exchanger)
Y1S
Solenoid valve (4‑way valve)
Y2S
Solenoid valve
Z1C~Z4C
Noise filter (ferrite core)
Z1F
Noise filter (with surge absorber) (A2P)
e
BP box (required to connect Residential Air (RA) or Sky Air
(SA) direct expansion (DX) indoor units)
f
Residential Air (RA) direct expansion (DX) indoor units
g
User interface (wireless, dedicated depending on indoor
unit type)
11

User interface

CAUTION
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch and appliance problems may happen.
For checking and adjusting the internal parts, contact your
dealer.
This operation manual will give a non-exhaustive overview of the
main functions of the system.
Detailed information on required actions to achieve certain functions
can be found in the dedicated installation and operation manual of
the indoor unit.
Refer to the operation manual of the installed user interface.
12

Operation

12.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.
Cooling
Outdoor
–5~52°C DB
temperature
Indoor
21~32°C DB
temperature
14~25°C WB
Indoor humidity
Heating
–20~21°C DB
–20~15.5°C WB
15~27°C DB
(a)
≤80%
RXYSQ8~12TMY1B
VRV IV-S system air conditioner
4P400263-1F – 2017.02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrv iv-s seriesRxysq10tmy1bRxysq12tmy1bRxysq-ty1

Table of Contents