Daikin RXYSQ4-6PAY Technical Data Manual

Daikin RXYSQ4-6PAY Technical Data Manual

Vrv iii-s rxysq4-6pay series air conditioner

Advertisement

Air Conditioners

Technical Data

V R V ® H e a t Pu m p
E E D E N 1 0 - 2 0 0
RXYSQ4-6PAY

Advertisement

Table of Contents
loading

Summary of Contents for Daikin RXYSQ4-6PAY

  • Page 1: Technical Data

    Air Conditioners Technical Data V R V ® H e a t Pu m p E E D E N 1 0 - 2 0 0 RXYSQ4-6PAY...
  • Page 2 Air Conditioners Technical Data V R V ® H e a t Pu m p E E D E N 1 0 - 2 0 0 RXYSQ4-6PAY...
  • Page 3: Table Of Contents

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY TABLE OF CONTENTS RXYSQ4-6PAY Specifications ............2 Technical Specifications .
  • Page 4: Specifications

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Specifications 1-1 Technical Specifications RXYSQ4PA7Y1B RXYSQ5PA7Y1B RXYSQ6PA7Y1B Capacity Cooling 11.2 14.0 15.5 Heating 12.5 16.0 18.0 Cooling 3.88 3.88 3.33 Heating 4.43 4.03 3.83 Capacity range PED category Category I...
  • Page 5 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Specifications 1-1 Technical Specifications RXYSQ4PA7Y1B RXYSQ5PA7Y1B RXYSQ6PA7Y1B Refrigerant Name R-410A Charge Control Expansion valve (electronic type) Nr of Circuits Refrigerant Oil Name Daphne FVC68D Charged Volume Piping connections Liquid (OD)
  • Page 6: Electrical Specifications (50Hz)

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Specifications 1-2 Electrical Specifications (50Hz) RXYSQ4PA7Y1B RXYSQ5PA7Y1B RXYSQ6PA7Y1B Power Supply Name Phase Frequency Voltage 380-415 Current Nominal running Cooling 5.30 6.77 7.79 current (RLA) Starting current (MSC) 5.30 6.77 7.79 Maximum Running Current 13.5...
  • Page 7: Options

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Options RXYSQ-PY1 Item RXYSQ4 RXYSQ5 RXYSQ6 Cool/heat selector KRC19-26A6 Fixing box KJB111A Refnet header KHRQ22M29H Refnet joint KHRQ22M20T Central drain plug KKPJ5F180 4TW26101-4A NOTES All options are kits ® • VRV...
  • Page 8: Capacity Tables

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 1 Cooling capacity tables RXYSQ4PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air 14,0 16.0...
  • Page 9 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 1 Cooling capacity tables RXYSQ4PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air 14,0 16.0...
  • Page 10 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 1 Cooling capacity tables RXYSQ5PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air 14,0 16.0...
  • Page 11 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 1 Cooling capacity tables RXYSQ5PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air 14,0 16.0...
  • Page 12 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 1 Cooling capacity tables RXYSQ6PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air 14,0 16.0...
  • Page 13 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 1 Cooling capacity tables RXYSQ6PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air 14,0 16.0...
  • Page 14: Heating Capacity Tables

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 2 Heating capacity tables RXYSQ4PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air temp.
  • Page 15 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 2 Heating capacity tables RXYSQ4PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Outdoor air temp. Combination Capacity 16.0...
  • Page 16 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 2 Heating capacity tables RXYSQ5PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air temp.
  • Page 17 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 2 Heating capacity tables RXYSQ5PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air temp.
  • Page 18 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 2 Heating capacity tables RXYSQ6PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air temp.
  • Page 19 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Capacity tables 3 - 2 Heating capacity tables RXYSQ6PAY1 TC: Total capacity (kW); PI: Power Input (kW) (Compressor + Outdoor fan motor) Indoor air temp. (°CWB) Combination Capacity Outdoor air temp.
  • Page 20: Dimensional Drawing & Centre Of Gravity

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Dimensional drawing & centre of gravity 4 - 1 Dimensional drawing RXYSQ-PAV1/PAY1 Hole for anchor MODEL bolt 4-M12 RXYSQ4PA7V1B Ø15.9 FLARE RXYSQ5PA7V1B Ø15.9 FLARE RXYSQ6PA7V1B Ø19.1 BRAZING RXYSQ4PA7Y1B Ø15.9 FLARE RXYSQ5PA7Y1B Ø15.9 FLARE...
  • Page 21: Piping Diagram

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Piping diagram RXYSQ-PY1 Electronic expansion valve Electronic expansion Double pipe heat valve exchanger Filter Heat exchanger Pressure regulating valve Filter Service port 4-way valve High pressure Service port sensor Low pressure sensor...
  • Page 22: Wiring Diagram

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Wiring diagram 6 - 1 Wiring diagram RXYSQ-PAY OUTDOOR (NOTE 2) SELECTOR TO IN/D UNIT TO OUT/D UNIT POSITION OF COMPRESSOR U TERMINAL HEAT WIRE ENTRANCE AIR CONTROL COOL (NOTE 5)
  • Page 23: External Connection Diagram

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Wiring diagram 6 - 2 External connection diagram RXYSQ-PY1 Notes) 1 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes.
  • Page 24: Sound Data

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Sound data 7 - 1 Sound pressure spectrum RXYSQ4PY1 - Cooling RXYSQ4PY1 - Heating 4D057920 4D057923 approximate approximate threshold hearing for threshold hearing for continuous noise continuous noise Octave band center frequency (Hz)
  • Page 25 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Sound data 7 - 1 Sound pressure spectrum RXYSQ6PY1 - Cooling 4D057922 RXYSQ6PY1 - Heating 4D057925 approximate approximate threshold hearing for threshold hearing for continuous noise continuous noise Octave band center frequency (Hz)
  • Page 26: Sound Power Spectrum

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Sound data 7 - 2 Sound power spectrum RXYSQ4PY1 RXYSQ5PY1 Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW29227-3 3TW29237-3 NOTES NOTES dBA = A-weighted sound power level (A-scale according to IEC)
  • Page 27: Installation

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Installation 8 - 1 Service space RXYSQ-PY1 (2) Where there is an obstacle on the discharge side Required installation space (a) No obstacle above The unit of the values is mm.
  • Page 28 ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Installation 8 - 1 Service space Series installation. RXYSQ-PY1 (b) Obstacle above, too 500 or less Stand-alone installation. The relations between H, A and L are The relations between H, A and L are as follows.
  • Page 29: Operation Range

    ® • Outdoor Units • VRV Heat Pump • RXYSQ4-6PAY Operation range RXYSQ-PY1 Cooling Heating Range for operation Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: These figures assume the following operating conditions. 3D045713C Indoor and outdoor units: • Equivalent piping length 7.5m...
  • Page 31 The present publication is drawn up by way of information only and does not constitute an offer binding conditioning equipment, compressors and refrigerants upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its has led to its close involvement in environmental issues.