Download Print this page

TriangleTube Instinct Solo 110 Instructions

Natural to propane conversion
Hide thumbs Also See for Instinct Solo 110:

Advertisement

Quick Links

Kit Part Number
INSRKIT131 (Solo 110)
INSRKIT132 (Solo/Combi 155)
INSRKIT133 (Solo/Combi 199)
Kit Includes
Rating Label
Conversion Label
(1) Propane Gas Venturi
Recommended Tools
Adjustable Wrench / 10 mm Socket & Ratchet
Phillips Head Screwdriver
Flat Head Screwdriver
Calibrated Combustion Analyzer
WARNING
!
Indicates a potentially hazardous situation which,
if ignored, can result in serious injury or substan-
tial property damage.
WARNING
!
For your safety, turn off electrical power supply
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
NOTICE
Upon completion of the conversion from Natural to Pro-
pane, affix the new rating label included in the kit to the
unit adjacent to the existing rating label. DO NOT affix
the new label over the existing rating label. Add propane
conversion labeling to the gas valve.
223042 A01
Revision Date: 1/6/2022
Instinct Solo/Combi
Natural to Propane Conversion Instructions
NOTICE
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
WARNING
!
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
Instructions are for a qualified installer/ ser-
vice technician only.
Read all instructions before proceeding.
Follow instructions in proper order.
NOTICE
These instructions cover NG to LP conversion for Instinct
boilers only. Each kit is supplied with one venturi suitable
for use with that particular boiler model.
2019-18 Instinct NG to LP Conversion

Advertisement

loading
Need help?

Need help?

Do you have a question about the Instinct Solo 110 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TriangleTube Instinct Solo 110

  • Page 1 Instinct Solo/Combi Natural to Propane Conversion Instructions Kit Part Number • INSRKIT131 (Solo 110) • INSRKIT132 (Solo/Combi 155) • INSRKIT133 (Solo/Combi 199) Kit Includes • Rating Label • Conversion Label • (1) Propane Gas Venturi Recommended Tools • Adjustable Wrench / 10 mm Socket & Ratchet •...
  • Page 2: Electrical Shock Hazard

    INSTINCT NATURAL TO PROPANE CONVERSION INSTRUCTIONS 1. Preliminary Instructions: 1. Verify that the venturi replacement kit is correct for the model of boiler. See page 1. 2. Turn off electrical power supply to the boiler. 3. Close the manual gas shut off valve to the unit. 4.
  • Page 3 INSTINCT NATURAL TO PROPANE CONVERSION INSTRUCTIONS 7. Attach the propane conversion label to the gas WARNING valve and the propane conversion rating label next to the existing rating label Failure to retain the O-ring gasket between the ventu- ri and the blower will cause an improper seal resulting 8.
  • Page 4 INSTINCT NATURAL TO PROPANE CONVERSION INSTRUCTIONS 4. Combustion Test and Adjustments NOTICE NOTICE An adequate CH load must be present to dissipate the heat The installer MUST perform a complete combustion check generated during the combustion test. If an adequate CH load is not available, an indirect water heater can be used to to ensure the following combustion levels are met at high and low input firing rates and the burner is operating at op-...
  • Page 5 INSTINCT NATURAL TO PROPANE CONVERSION INSTRUCTIONS Table 1: Combustion Settings Fig. 6: Throttle Screw Location...

This manual is also suitable for:

Instinct solo 155Instinct solo 199Instinct combi 155Instinct combi 199Insrkit131Insrkit132 ... Show all