Download Print this page

TriangleTube Instinct Solo 110 Application Manual

Hide thumbs Also See for Instinct Solo 110:

Advertisement

Quick Links

Application
Guide
S O LO 1 1 0 - 1 55 - 199 & CO M B I 1 5 5 - 19 9
This manual is applicable to all Instinct boilers with AB in the serial number after the S or C (e.g. IN110SAB000001) which also
operate with software version 0.36 / 0.60 or earlier.
If this guide does not apply to your boiler, Please visit triangletube.com to obtain the correct application guide.
This document is intended to be used by a
factory trained and qualified heating contractor
or service technician only. Read all Instructions
within this document and within the relevant
Boiler Installation and Maintenance Manual
before proceeding. It is recommended to follow
When receiving the Instinct unit, any claims for damage or shortage in shipment must be filed immediately against the
transportation company by the consignee.
Customer must register unit within sixty (60) days of installation in order to gain warranty coverage. See Warranty Card for
details.
Leave all documentation received with appliance with the owner for future reference.
Installation and service should only be performed by a qualified installer or service technician.
Installations and service should be performed by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
2020-52B - Instinct Application Book
February 25, 2021
NOTICE
WARNING
the procedures in the steps given. This guide does
not replace the Installation and Maintenance
manual. Skipping or missing procedural steps
could result in substantial property damage,
serious injury, or death.
NOTICE
T H E
O R I G I N A L
I N N O V A T O R S

Advertisement

loading
Need help?

Need help?

Do you have a question about the Instinct Solo 110 and is the answer not in the manual?

Questions and answers

Summary of Contents for TriangleTube Instinct Solo 110

  • Page 1 This manual is applicable to all Instinct boilers with AB in the serial number after the S or C (e.g. IN110SAB000001) which also operate with software version 0.36 / 0.60 or earlier. • If this guide does not apply to your boiler, Please visit triangletube.com to obtain the correct application guide. WARNING This document is intended to be used by a the procedures in the steps given.
  • Page 2 Instinct Application Guide Sections 1. Boiler Pump Presets ......................................3 3. Flexible Pump Configuration .................................... 4 4. Pump Selection ........................................7 5. Instinct Solo Piping Diagrams ..................................8 6. Instinct Combi Piping Diagrams ..................................20 Figures Fig.
  • Page 3 Instinct Application Guide 4. Press the OK button while the Boiler Settings icon 1. Boiler Pump Presets is highlighted. The boiler comes preconfigured for several preset pump outputs. 1. To access the Installer screen, touching simultane- ously the up and down soft keys for 3 seconds as shown in Fig.
  • Page 4 Instinct Application Guide Table 1: Instinct Preset Pump Configurations Preset Boiler Pump CH1 Pump CH2 Pump DHW Pump Configuration Instinct 1 CH1 Call CH1 Call CH2 Call CH2 Call DHW Call DHW Call Instinct 2 CH1 Call CH1 Call CH1 Call CH2 Call CH2 Call CH2 Call...
  • Page 5 Instinct Application Guide 3. Flexible Pump Configuration This allows the installer to customize the flexible Pump Output (relays) to a specific installation arrangement that is not addressed in the Preset Pump Configuration options. There is a total of six Pump Output(relays) that must be set.
  • Page 6 Instinct Application Guide 7. A list of 5 Flex Relays are clickable. These are the on the pump wired to the boiler pump terminal for Boiler actions to be edited. CH1, CH2 and DHW calls. Fig. 15: Flex. Relay 1 Settings Fig.
  • Page 7 Instinct Application Guide 4. Pump Selection Refer to Table 2 for the Boiler pump recommendations when using primary secondary piping. Table 2: Instinct Solo Pump Requirements Model Heating Temperature Required Minimum Minimum Boiler Pump Size Capacity Rise Boiler Flow Boiler Pipe Size Grundfos Taco...
  • Page 8 Instinct Application Guide 5. Instinct Solo Piping Diagrams Fig. 17: Instinct Solo Near Boiler Piping with Closely Spaced Tees Fig. 18: Instinct Solo Near Boiler Piping with Hydraulic Separator...
  • Page 9 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 19: Instinct Solo - Multiple Zones with Circulators NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 10 Instinct Application Guide Instinct 3 Pump Configuration Instinct 3 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 20: Instinct Solo - Multiple Zones with Circulators - Domestic Piping Alternate NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 11 Instinct Application Guide Instinct 2 Pump Configuration Instinct 2 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 21: Instinct Solo - Piping with Zone Valves NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 12: Boiler Pump

    Instinct Application Guide Instinct 4 Pump Configuration Instinct 4 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 22: Instinct Solo - Piping with Zone Valves - Domestic Piping Alternate NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 13 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 23: Instinct Solo - Piping with Zone Valves and Zone Valve Control Panel NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 14 Instinct Application Guide Instinct 3 Pump Configuration Instinct 3 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 24: Instinct Solo - Piping with Zone Valves and Zone Valve Control Panel - Domestic Piping Alternate NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 15 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 25: Instinct Solo - Single Zone with Circulator NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 16 Instinct Application Guide Instinct 3 Pump Configuration Instinct 3 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 26: Instinct Solo - Single Zone with Circulator - Domestic Piping Alternate NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 17 Instinct Application Guide Instinct 3 Pump Configuration Instinct 3 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 27: Instinct Solo - Multiple Temperature Zones with Circulators NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 18 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 28: Instinct Solo - Multiple Temperature Zones with Circulators - Domestic Piping Alternate NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 19 Instinct Application Guide Fig. 29: Instinct Solo - Cascade Layout...
  • Page 20 Instinct Application Guide 6. Instinct Combi Piping Diagrams Fig. 30: Instinct Combi Near Boiler Piping with Timesaver Manifold Fig. 31: Instinct Combi Near Boiler Piping with Hydraulic Separator...
  • Page 21 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 32: Instinct Combi - Multiple Zones with Circulators NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 22 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 33: Instinct Combi - Single Zones with Circulator NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 23 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 34: Instinct Combi - Multiple Temperature Zones with Circulators NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 24 Instinct Application Guide Instinct 2 Pump Configuration Instinct 2 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 35: Instinct Combi - Multiple Zones with Zone Valves NOTICE Piping layout is shown with a Hydraulic Separator.
  • Page 25 Instinct Application Guide Instinct 1 Pump Configuration Instinct 1 Pump Configuration Heat Call Heat Call Boiler Pump Boiler Pump CH1 Pump CH1 Pump CH2 Pump CH2 Pump DHW Pump DHW Pump Fig. 36: Instinct Combi - Multiple Zones with Zone Valves and Zone Valve Control Panel NOTICE Piping layout is shown with a Hydraulic Separator.