Masonry Chimney Conversions - FireplaceXtrordinair 564 GSR2 25K CF Installation Manual

Table of Contents

Advertisement

32
Finalizing the Installation

Masonry Chimney Conversions

This appliance may utilize 6-5/8" diameter direct vent manufactured by Duravent (reducer may be required). The vent
may be adapted to utilize an existing masonry fireplace using the Duravent Co-Linear Adapter (46DVA-GCL or TCL).
The vent must be installed following all directions included with the vent and those listed below:
All requirements in the appliance
manual must be met. This
includes compliance with vent
configuration charts.
The restrictor position should be
set to the position that most
closely resembles the vent
configuration. NOTE: because
this installation utilizes non-
standard vent, the restrictor
position may vary. Carefully
monitor the burn characteristics to
verify correct restrictor position.
The UL gas liner must only be run
through the fireplace/chimney
(entire length of liner must be
retained within the
fireplace/chimney). Do not run
the liner near combustibles.
This appliance may utilize 6-5/8" diameter direct vent manufactured by Duravent (reducer may be required). The vent
may be adapted to utilize an existing masonry fireplace using the Duravent Masonry Chimney Conversion Kit (part #
46DVA-KCT). The vent must be installed following all directions included with the vent and those listed below:
NOTE: Before proceeding with the following installation example, check with the local building jurisdiction to
verify that this type of installation is allowed in your area.
All requirements in the appliance
manual must be met. This
includes compliance with vent
configuration charts.
The restrictor position should be
set to the position that most
closely resembles the vent
configuration. NOTE: because
this installation utilizes non-
standard vent, the restrictor
position may vary. Carefully
monitor the burn characteristics to
verify correct restrictor position.
The UL gas liner must only be run
through the fireplace/chimney
(entire length of liner must be
retained within the
fireplace/chimney). Do not run
the liner near combustibles.
© Travis Industries
Co-Axial to Co-Linear Adapter must
maintain 3" clearance to combustibles
Coaxial pipe must maintain proper
clearances to combustibles
(see manual for details).
Direct Vent
Direct Vent
Fireplace
The entire chimney system must be air-tight.
Make sure to seal the flashing, clean-out, and
thimble connection, and to inspect the
chimney.
Make sure the coaxial pipe maintains the correct
clearance to any combustible (see the owner's manual).
The vent must be sealed air-tight.
5/8/2019 - 1505
(for qualified installers only)
High Wind Termination
Flashing
UL Gas Liner
Flashing (included in
#934 Masonry
Conversion Kit)
4" Dia. Flex Line
(UL 1777 Gas Liner)
Connector with Cover
(included in #934 Masonry
Conversion Kit)
564 GSR2 25K CF