Installation manual
15
4.3 Siting
The figure shows recommended distance to walls and/or other machines.
B
A
A
fig.X00959
Note!
The machine should be positioned so that there will be enough space for working, both for the user and
service personnel.
Respecting the given recommendations will provide easy access for maintenance and service operations.
In case of space limitations, it is possible to install machines without respecting to the given recommendations. If so,
keep in mind that it might be necessary to disconnect and move other machines to be able to reach and perform
service on affected machine.
4.4 Drain connection (only for machines with heat pump)
Connect the drain to the heat pump unit.
Note!
The outlet condense water (4) and the cooling water (5) must be connected to separate outlets.
The hose (4) must be positioned over the water level in the floor drain.
Note!
The drain must be lower than the drain outlet from the heat pump unit. If not the water will flow back into the
machine. Adjust with the feet.
The hoses shall hang in gentle arcs.
fig.W00609