Enable or Disable Anti-Passback Forgiveness at Midnight:
If you Enable the anti-passback forgiveness feature, All entry codes, cards, transmitters
will be reset at midnight each day. The system will grant entry/exit and "forgive" any
errors from the previous day.
Press
1
Enable or Disable Utility Option:
Factory Setting: Disabled
Press
1
Enter Utility Option (0-3). Then (#)
2
Option 0=Off; Option 1=Resets Daily (number of uses resets to the original programmed
value everyday at midnight); Option 2=Resets Weekly (number of uses resets to the original
programmed value every week); Option 3=Never Reset (number of uses continue to
decrease until the value is 0-the number never resets)
When an alarm is triggered, the system can activate (energize) one or more relays. A
relay can sound a siren, turn on a flashing red light, turn on a closed circuited
television (CCTV), or trigger other mechanisms.
Configure "Door Held Open" Alarm Feature:
When enabled, doors can be programmed to trigger an alarm when they are held open to
long. The alarm will activate the relays you specify. The relays can remain active until the
relay time expires or until the alarm condition clears.
Press
1
Enter Alarm Option (0-2). Then (#)
2
Option 0=Disabled
Option 1= Enabled Relays will activate until relay time expires
(See Set Relay Activation Time on page 23 (Step 3) for more information)
Option 2=Enabled Relays will activate until the alarm condition clears (e.g., the door is
closed from the "door held open" alarm condition)
Activate (1) or Deactivate (0) Relays (0000-1111). Then (#)
3
Example:
When a "Door Held Open" alarm condition occurs, relay "3" will activate until the alarm
condition clears. If the alarm relay controls a flashing light, the light will turn off when
the door is closed.
Factory Setting: Enabled
Then
2
58
NOTE: The last option can be ignored if the
Then
utility feature is currently OFF.
Configure the Alarm Features
Then
(1st digit=Relay 4, 2nd digit=Relay 3, etc.)
1
2
Page 54
Enable (1) or Disable (0). Then (#)
102
Factory Setting: Disabled
Relay 4
Relay 3 Relay 2 Relay 1
3
Deact Activate Deact Deact
105

Advertisement