electrolux e:line ovens installation

Installation

warning
Please follow the points below when installing the appliance
Use an authorised person
• As stated in the local municipal building codes and
other relevant statutory regulations:
• Wiring connections must be in accordance with AS/NZS
3000 Wiring Rules and any particular conditions of the
local authority.
• Refer to data plate for rating information. The data
plate is positioned behind the bottom of the oven door.
The circuit diagram is positioned on the top panel of
the appliance.
• For appliances with open cooking surfaces, an all pole
disconnect functional switch should be provided near
the appliance in an accessible position. Refer to AS/
NZS 3000 clause 4.7.1
• Wiring should be protected against mechanical failure.
Refer to AS/NZS3000 clauses 3.3.2.6, 3.9, 3.10
• A means of disconnection with a contact separation of
at least 3mm must be supplied in the fixed wiring.
warning
This appliance must be properly earthed.
• Do not lift the appliance by the door handles.
• Prepare the cupboard opening to match your appliance
measurements. (See diagrams)
• Slide appliance into the cupboard, ensuring that the
supply cable (where fitted) does not kink.
• To prevent tipping, use the screws supplied to secure
your oven into the cupboard by fastening through the
2 holes to the front panel.
• Where the appliance is built into a cabinet, the cabinet
must be capable of withstanding 70°C. Installation into
low temperature tolerant cabinetry (e.g. Vinyl coated)
may result in deterioration of the low temperature
coating by discolouring or bubbling.
• If the appliance is to be installed adjacent to vinyl
wrapped surfaces, use an installation kit available from
the vinyl-wrap supplier.
• Electrolux Home Products cannot accept responsibility
for damage caused by installation into low temperature
tolerant cabinets.
• After installation, test and ensure that the appliance
operates correctly before handing it over to the
customer.
Note:
• I f a powerpoint is fitted it must be accessible with the
appliance installed, as the plug must be accessible
after installation.
warning
To avoid any potential hazard, you must follow our
instructions when you install your appliance. Failure
to install the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
Cabinet construction for your appliance
For the best integration within a kitchen, install this appliance
in a standard 600mm wide cupboard that gives a flush fit
with the surrounding cupboard fronts. It can also be installed
using a proud fit.
Flush Fit
Cupboard
door
Proud Fit
Cupboard
door
Note:
Your appliance must be mounted on a flat surface for the
full width and depth of the product
warning
IMPORTANT: The infill panel MUST not exceed
100mm in length to ensure a 16mm gap is
maintained
16mm
568mm
Infill
100mm
panel
max for
Pyro oven
20mm
Oven
600mm
16mm
568mm
Infill
100mm
panel
max for
Pyro oven
Oven
600mm