Mrkcnt (Set Number Of Markers); Mrklvl (Set Starting Level Of Markers); Mrkdis (Marker Display Mode) - Aaronia NF-5030S Manual

Table of Contents

Advertisement

7.16 UScale (Set scaling of physical unit)
UScale allows you to choose the prefix of the physical unit.
Selecting "Auto" automatically selects the prefix ("p", "n", "µ", "m", "k"). However,
you can also set a fixed prefix, where possible options are: "p" (Pico), "n" (Nano),
"µ" (Micro), "m" (Milli), "Unit" (only full units WITHOUT prefix) and "k" (Kilo).

7.17 MrkCnt (Set number of markers)

MrkCnt is used to set the number of markers. Possible values are 1,2 or 3.
If you only need to measure one frequency you should reduce the number of
markers to "1". Then you will get a very stable display with no "jumping" markers
after every sweep.

7.18 MrkLvl (Set starting level of markers)

MrkLvl is used to set a specific signal strength from which markers are gene-
rated and exposure limit calculations are performed. Available settings range
from 20% to 80% and correspond to the relative height of the peaks in the bar-
graph display.

7.19 MrkDis (Marker display mode)

The marker display mode determines how markers are displayed. As the avai-
lable display space for showing markers very differs in size and readability, two
different modes are available:
Freq. (frequency) displays the frequency of each marker in the large display. Its
amplitude (or similar applicable property) is small displayed beneith the fre-
quency.
Ampl. (amplitude) displays the amplitude (or similar property) of each marker in
large, and the frequency in the smaller display field. Usually, the Freq. mode will
be preferred as the frequency usually is the most important piece of information
and therefore should be the most readable as well.
Freq.
(larger frequency display)
30
Firmware V 1.0 / © 2005-2013 by Aaronia AG, D-54597 Euscheid, www.aaronia.com
At the 80% setting, markers are only generated with relati-
vely strong signals, compared to the 20% setting, where far
100%
80%
weaker signals, but also potential interference, are shown
60%
as markers. The default (60%) offers the best balance of
40%
20%
both extremes in most cases.
Amp.
7.0 The main menu
(larger amplitude display)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spectran nf

Table of Contents