Sign In
Upload
Manuals
Brands
Aaronia Manuals
Measuring Instruments
Spectran V4
Aaronia Spectran V4 Manuals
Manuals and User Guides for Aaronia Spectran V4. We have
3
Aaronia Spectran V4 manuals available for free PDF download: User Manual, Manual
Aaronia Spectran V4 Manual (85 pages)
Spectrum Analyzer
Brand:
Aaronia
| Category:
Measuring Instruments
| Size: 13 MB
Table of Contents
Table of Contents
2
1 Introduction
6
Liability
6
Warranty
6
Safety Guidelines
7
Scope of Delivery
8
2 Connections
10
Jog Dial / Volume Control
10
USB Connector
10
Audio Output
11
3 Power Connection
11
External DC Input (Battery Charger / Mains Operation)
11
Operating with an External Power Supply
12
4 Overview Front Panel
13
Operating Equipment
13
Numeric Block (Hotkeys)
14
LC Display
15
The Display Shows
16
5 Functional Description
17
Technical Data
17
Main Menu
18
Menu Items
19
Center (Center Frequency)
19
Span (Frequency Range Width)
19
Flow & Fhigh (Start & Stop Frequency)
20
RBW (Bandwidth)
21
VBW (Video Filter)
21
Swtime (Sweep-Time)
22
Reflev (Referenz-Level)
22
Range (Dynamics)
23
Atten (Attenuator)
24
Preamp (Internal Pre-Amplifier / Option 020)
24
Demod (Demodulator /Audio-Analysis/Gsm-Decoder)
25
Demod (GSM-Decoder)
26
Audind (Audio-Indicator / "Bug Tracer" - Option 015)
26
Detect (Detector Type)
27
Disp (Display Mode)
28
Unit (Set Unit)
29
Mrkcnt (Set Number of Markers)
30
Marklvl (Set Starting Level for Markers)
30
Mrkdis (Marker Display Mode)
31
Backbb (Change Bargraph Display Mode, Option 20X)
32
Anttyp (Configure Connected Antenna)
32
Cable (Configure Antenna Connection Cable / Attenuator)
33
Refoff (Set Offset or UBBV-Preamplifier)
33
Gsmbst (Select GSM Burst-Type)
34
Gsmdst (GSM Slot-Distance)
34
Calib ( in Preparation, Currently Not Usable)
34
Bright (Set Display Brightness)
34
Logger (Start Recording/Data Logger)
35
Setup (Organize Programs)
38
6 First Operational Steps
40
One-Hand Operation
41
Omnilog 90200
42
Pistolengriff
42
Hardware-Setup
43
7 Correct Measurement
45
Noise Floor
45
Harmonics
46
Measurement of Wireless LAN & Cellphones
46
Attenuator-Mode „Auto
47
Sensitivity
47
Measurement Inaccuracy
48
The Cursor and Zoom Features
49
8 First Measurement
50
Prepair Device
50
Basics
50
Measurement
50
Operation Mode „Spectrum Analysis
50
Hold-Function
51
The „Panning Approach
52
Operation Mode "Exposure Limit Calculation
52
Operation Mode Audio-Output (Demodulation)
54
Operation Mode Broadband Detector (Peak Power Meter)
57
Manual Setting of a Frequency Range
59
9 Tips and Tricks
61
Quick Zero-Span Sweep (Time Domain Mode)
61
Turbo"Sweep for Small Frequency Ranges
61
Turbo"Sweep for Larger Frequency Ranges
62
Allocating Keys with Your Own Measurement Settings
62
Dect Analysis
62
Exposure Limit Calculation
63
Conversion of Measurement Results to Other Units
63
Correct Settings for Manual Input/Measurement
63
Measurement of Satellite TV
64
Measurement with a Direct Cable Connection
64
10 Spectrum Analysis Basics
65
What Is a Frequency Range
65
Big Difference between Exposure Limits
65
Application of Spectrum Analysis
66
11 Physical Units
70
Measuring Transmission Power (Dbm; DbµV)
70
Field Strength [V/M; A/M] and Power Density [W/M²]
70
Interesting Facts Regarding High-Frequency Formula
71
Calculating the Wavelength in [M]
72
Calculating the „Close-Up Range" in [M]
73
Calculating Power Density [W/M²] from Power [Dbm]
73
12 Tables and Exposure Limits
74
Convesion Tables
74
Table 2: Conversion from W/M² to Μw/CM² and Mw/CM²
76
Table 5: Frequency, Wavelength and Frequency Band Denomination
77
Frequency Tables
78
Table 9: German GSM1800 Frequencies and Providers
79
Table 10: German UMTS Frequencies and Providers
80
Exposure Limits
81
Device Exposure Limits
83
Advertisement
Aaronia Spectran V4 User Manual (123 pages)
Remote Spectrum Analyzer (RSA) with EMF Monitor Software
Brand:
Aaronia
| Category:
Measuring Instruments
| Size: 12 MB
Table of Contents
Table of Contents
2
Quick Installation Guide
4
1 Connecting the Cables
5
2 Configure the RSA to Client Pc Network Connection
6
2.1 Configure Your Windows 7 Client PC for the RSA Network Connection
7
2.2 Configure Your Macosx Client PC for the RSA Network Connection
11
2.3 Configure Your Linux Client PC for the RSA Network Connection
13
3 Remote Connection Via MCS Software
16
4 Remote Connection Via Webbrowser (EMF Monitor Software)
19
5 Rsa - Defaults
22
Users Guide
23
Requirements
24
Hardware Overview
25
Getting Started
27
Stand-Alone Installation
28
Assembly Instructions
29
RSA Webinterface
31
Home (Index) Page
32
System Overview
34
Spectran Server Overview
35
Clients Overview
37
Contact Information
39
Server Logfile
41
User Management
43
Add New User
44
Edit User
45
System Configuration
46
Network Configuration
47
Configure on Local Machine in the Desktop Environment
48
Boot the System
49
Open Webbrowser
51
Login Page
53
Administration Area
54
Ipv4 Configuration
56
Ipv6 Configuration
59
Configure with Remote Computer over a Network Connection
61
Date and Timezone Configuration
62
System Updates
64
Spectran Server Configuration
65
Email Notification
71
Sweep Profile Editor
73
Frequency Dialog
76
Batch Recording Manager
77
Trigger Editor
80
Manage Local Recordings
83
System Control
87
Demodulation Control
89
VLC Media Player Example
91
Help & Information
92
RSA SPECTRAN Server TCP/IP Command API
93
Specific Commands Defined in GPIB Standard
94
Server Commands (SERVER)
96
Information Commands (SPECTRAN:INFO)
98
Control Commands (SPECTRAN:CTRL)
100
Calculation Commands (SPECTRAN:CALC)
106
Protocol Types
109
Faq
115
How to Connect to the RSA When It Is Integrated into the Network Without Monitor and Keyboard
116
Operating System Updates
117
Administration Page Shows Error Instead of Measurements
118
We'D Like Use the RSA as Desktop PC with MCS Software, Is It Possible
120
Fix Network Problems
121
How to Update to the Latest Version
122
Aaronia Spectran V4 User Manual (56 pages)
Brand:
Aaronia
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
2
Introduction
6
Liability
6
Warranty
6
Safety Guidelines
6
Scope of Delivery
7
Connections
8
Jog Dial/Volume Control
8
USB Connector
8
Audio Output
8
Power Connection
9
External DC Input (Battery Charger / Mains Operation)
9
Operating with an External Power Supply
9
Overview Front Panel
10
Operating Equipment
10
Numeric Block (Hotkeys)
11
LC Display
12
The Display Shows
13
Functional Description
14
Technical Data
14
Main Menu
15
Menu Items
16
Center (Center Frequency)
16
Span (Frequency Range Width)
16
Flow & Fhigh (Start & Stop Frequency)
16
RBW (Bandwidth)
17
VBW (Video-Filter)
17
Swtime (Sweep-Time)
18
Reflev (Reference-Level)
18
Range (Dynamics)
18
Functional Description
19
Atten (Attenuator)
19
Preamp (Internal Pre-Amplifier / Option 020)
19
Demod (Demodulator/Audio Analysis)
19
Demod (GSM-Decoder)
19
Audind (Audio-Indicator / "Bug Tracer" - Option 015)
20
Detect (Detector Type)
20
Disp (Display Mode)
21
Unit (Set Unit)
21
Mrkcnt (Set Number of Markers)
21
Marklvl (Set Starting Level for Markers)
21
Mrkdis (Marker Display Mode)
22
Backbb (Change Bargraph Display Mode, Option 20X)
22
Anttyp (Configure Connected Antenna)
22
Cable (Configure Antenna Connection Cable / Attenuator)
22
Refoff (Set Offset or UBBV-Preamplifier)
22
Gsmbst (Select GSM Burst-Type)
23
Gsmdst (GSM Slot-Distance)
23
Calib (in Preparation, Currently Not Usable)
23
Bright (Set Display Brightness)
23
Logger (Start Recording/Data Logger)
23
Runprg (Run Program)
24
Setup (Organize Programs)
24
First Operational Steps
25
One-Hand Operation
25
Omnilog 90200
26
Pistol Grip
27
Hardware Setup
27
Correct Measurement
28
Noise Floor
28
Harmonics
28
Measurement of Wireless LAN & Cellphones
28
Attenuator-Mode „Auto
29
Sensitivity
29
Measurement Inaccuracy
29
Cursor and Zoom Features
30
First Measurement
31
Prepair Device
31
Basics
31
Measurement
31
Operation Mode „Spectrum Analysis
31
Hold-Function
32
The „Panning Approach
33
Operation Mode "Exposure Limit Calculation
33
Operation Mode Audio-Output (Demodulation)
34
Operation Mode Broadband Detector (Peak Power Meter)
35
Manual Setting of a Frequency Range
37
Tips and Tricks
38
Quick Zero-Span Sweep (Time Domain Mode)
38
Turbo"Sweep for Small Frequency Ranges
38
Turbo"Sweep for Larger Frequency Ranges
38
Allocating Keys with Your Own Measurement Settings
38
Dect Analysis
38
Exposure Limit Calculation (Display in W/M² with „Weak" Signals)
38
Conversion of Measurement Results to Other Units
38
Correct Settings for Manual Input/Measurement
39
Measurement of Satellite TV
39
Kabelgebundene Messungen
39
Measurement with a Direct Cable Connection
39
Spectrum Analysis Basics
40
What Is a Frequency Range
40
Big Difference between Exposure Limits
40
Application of Spectrum Analysis
40
Physical Units
43
Measuring Transmission Power (Dbm; DbµV)
43
Field Strength [V/M; A/M] and Power Density [W/M²]
43
Interesting Facts Regarding High-Frequency Formula
43
Calculating the Wavelength in [M]
44
Calculating the "Close-Up Range" in [M]
44
Calculating Power Density [W/M²] from Power [Dbm]
44
Tables and Exposure Limits
45
Convesion Tables
45
Frequency Tables
47
Exposure Limits
49
Device Exposure Limits
50
Description / Types | Safety Instructions
52
Disposal | Technical Data | CE Compliance / Disclaimer
54
Advertisement
Advertisement
Related Products
Aaronia SPECTRAN V5
Aaronia SPECTRAN HF-2025E
Aaronia SPECTRAN HF-6080
Aaronia SPECTRAN NF-5010
Aaronia SPECTRAN HF-2025
Aaronia SPECTRAN HF-4060
Aaronia SPECTRAN NF
Aaronia NF-5030S
Aaronia Categories
Measuring Instruments
Portable Generator
Amplifier
Antenna
Inverter
More Aaronia Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL