Notes:
1.Power input to Door
Operator Unit is at "T1"
Power Input Terminal (not
shown) 120VAC 60Hz.
Operation:
Doors are normally closed.
•
Activating either switch will
•
open both doors. Door will
close after hold open time
delay has elapsed.
Notes:
1.Power input to Door Operator
Unit is at "T1" Power Input
Terminal (not shown) 120VAC
60Hz.
2. Radio Frequency Feature can
be purchased as a separate kit.
Fault
The door does not open
- The motor does not start
- The motor starts
The door does not close
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Standard Function with Switches
1
1
2
2
3
3
4
4
Door 1
Radio Frequency Function Option
1.1A 24V Power Supply
L
N
-V
(AC)
120
VAC
Troubleshooting
Possible reasons why
Control switch is set to OFF position
Circuit breaker is set to OFF position
Electrical power is missing
Activation unit does not function
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Spring tension too low
Arm has come loose
Something jammed beneath the door
Wall Switch, Card
Reader, Key Switch,
etc.
Wall Switch, Card
Reader, Key Switch,
etc.
+
+V
ADJ
Remedies/Explanations
Change the setting of the ON/OFF switch
Reset circuit breaker to the ON position
Check
the electrical
Jump activation input
Flip Door Mounting Dip Switch to other direction
Remove object
Re-time and re-install arm.
Increase spring tension per preceding instructions
Re-time and re-install arm.
Remove object
Page 10
ASSA ABLOY
Normally Open Momentary
dry contacts
1
1
2
2
3
3
4
4
Door 2
Normally Open Momentary
dry contacts
Optional Door 2
Operation:
Door is normally
•
closed.
Activating wireless
•
switch or hand held
wireless transmitter
will open the door.
Door will close after
•
Door 1
hold open delay
elapses.
power switch
80-9357-0008-020 (Rev 3)