Electrical Connection - Lang PF-H-1 Installation Operation & Maintenance

Half size proofer
Table of Contents

Advertisement

THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST SHOCK
HAZARD AND MUST BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED 3-PRONG RECEPTACLE.
DO NOT CUT OR REMOVE THIS GROUNDING PRONG FROM THE PLUG.
120 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local codes with
NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1).
The electrical service entrance is provided by a cord and plug.
Each appliance requires a 120 volt grounded supply and 16.7 amps.
Supply wire size must be 14 gauge or larger to carry the load for one proofer.
The plug type is NEMA S-20P, match the plug to the corresponding NEMA S-20R for the receptacle
(receptacle not supplied).
240 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local codes with
NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1).
The electrical service entrance is provided by a cord and plug.
Each appliance requires a 240/208 volt grounded supply and 16.7 amps.
Supply wire size must be 14 gauge or larger to carry the load for one proofer.
The plug type is NEMA #6-15P, match the plug to the corresponding NEMA #6-15R for the receptacle
(receptacle not supplied).
VOLTAGE
120
240
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
AMPERAGE
13.0
6.5
4

ELECTRICAL CONNECTION

WATTAGE
1550
1550