Electrical Connection - Lang PFL 120 Installation, Operation, Maintenance And Service Instructions

Hinged proofer
Table of Contents

Advertisement

ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING)
PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND
MUST BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED 3-
PRONG RECEPTACLE.
DO NOT CUT OR REMOVE THIS GROUNDING PRONG FROM THE
PLUG.
120 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local
codes with NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1).
The electrical service entrance is provided by a cord and plug.
Each appliance requires a 120 volt grounded supply and 16.7 amps.
Supply wire size must be 14 gauge or larger to carry the load for one proofer.
The plug type is NEMA S-20P; match the plug to the corresponding NEMA S-20R for the receptacle
(receptacle not supplied).
240 Volt Models:
The electrical connection must be made in accordance with local codes or in the absence of local
codes with NFPA No. 70 latest edition (in Canada use: CAS STD. C22.1).
The electrical service entrance is provided by a cord and plug.
Each appliance requires a 240/208 volt grounded supply and 16.7 amps.
Supply wire size must be 14 gauge or larger to carry the load for one proofer.
The plug type is NEMA #6-15P, match the plug to the corresponding NEMA #6-15R for the
receptacle (receptacle not supplied).
VOLTAGE
120
240
WARNING
AMPERAGE
13.0
6.5
4

Electrical Connection

WATTAGE
1550
1550