Belt Maintenance; Checking The Alternator-Belt Tension; Controls System Maintenance; Adjusting The Control-Lever Neutral-Interlock Switch - Toro 30495TC Operator's Manual

Traction unit
Hide thumbs Also See for 30495TC:
Table of Contents

Advertisement

Belt Maintenance

Checking the
Alternator-Belt Tension
Service Interval: Every 100 hours
1.
Apply 44 N (10 lb) of force to the alternator belt,
midway between the pulleys.
2.
If the deflection is not 10 mm (3/8 inch), loosen
the alternator mounting bolts
Figure 47
1. Mounting bolt
3.
Increase or decrease the alternator-belt tension.
4.
Tighten the mounting bolts.
5.
Check the deflection of the belt again to ensure
that the tension is correct.
(Figure
47).
g008932
2. Alternator
Controls System
Maintenance
Adjusting the Control-Lever
Neutral-Interlock Switch
1.
Stop the machine, move the motion-control
levers to the N
parking brake, and remove the ignition key.
2.
Remove the bolts securing the front panel and
remove the panel
1. Bolt
2. Control panel
3.
Loosen the 2 screws securing the interlock
switch
(Figure
48
-
position, engage the
EUTRAL
LOCK
(Figure
48).
Figure 48
49).
g020875

Advertisement

Table of Contents
loading

This manual is also suitable for:

30495Groundsmaster 7200 series