Air purifying dehumidifier

Advertisement

Quick Links

DW-J27FV
DW-J27FM
DW-J20FM
"Plasmacluster" and "Device of a cluster of grapes" are
trademarks of Sharp Corporation.
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm
is measured around the center of a room with the "high-
density plasmacluster 7000" applicable floor area (at 1.2
m height above the floor) when the product is placed close
to a wall at the LAUNDRY Operation "DEODORIZE mode
setting.
AIR PURIFYING DEHUMIDIFIER
OPERATION MANUAL
SÁCH HƯỚNG DẪN SỬ DỤNG
MÁY LỌC KHÍ VÀ HÚT ẨM
3
, which

Advertisement

Table of Contents
loading

Summary of Contents for Sharp Plasmacluster DW-J27FV

  • Page 1 SÁCH HƯỚNG DẪN SỬ DỤNG MÁY LỌC KHÍ VÀ HÚT ẨM “Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation. * The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm , which is measured around the center of a room with the “high-...
  • Page 2: Table Of Contents

    ENGLISH Thank you for purchasing this SHARP Air Purifying Dehumidifier. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CONTENTS IMPORTANT SAFETY INSTRUCTIONS ............PART NAMES ....................PREPARATION ....................
  • Page 3 Wide angle louver swings to both top and bottom / left and right and provides wide-area air flow. AIR PURIFYING It collects toxic substances such as dust, pollen, airborne mold, unpleasant odor and purify the air through SHARP’s triple filters (HEPA Filter, Active Carbon Deodorizing Filter and Pre-filter) PM2.5 Monitor...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Always follow basic safety precautions • Only a Sharp Authorized Service when using electrical appliances, including Center should service this air purifying the following: dehumidifier. Contact the nearest Service Center for any problems, adjustments, or repairs. WARNING –...
  • Page 5 CAUTIONS CONCERNING INSTALLATION GUIDELINES OPERATION • Avoid locations where the sensors are exposed to direct wind. Doing so can cause • Do not block the air intake or air outlet. the Main Unit to malfunction. • Do not place the Main Unit near or on •...
  • Page 6: Part Names

    PART NAMES MAIN UNIT (FRONT) (BACK) Operation Panel Water Level Window Air Outlet Tank Knob Vertical Louver HEPA Filter Horizontal Louver Active Carbon Deodorizing Filter Main Unit Back Panel (Pre-Filter) Handle (2 Locations) Air Inlet Front Display Odor Sensor Water Tank Temperature/Humidity Sensor Drain Outlet Dust Sensitive Sensor, Sensor Filter...
  • Page 7 OPERATION PANEL Press the button with " " to start. Power ON/OFF Button H.SWING Button, Indicator Light MOLD CONTROL Button, Indicator Light ON/OFF TIMER Button AIR PURIFY Button, Indicator Light FILTER RESET Indicator Light LAUNDRY Button, Indicator Light INTERNAL DRY Indicator Light DEHUMIDIFY Button, Indicator Light Child-Lock Indicator Light HUMIDITY SELECT Button...
  • Page 8: Preparation

    PREPARATION FILTER INSTALLATION Remove the Back Panel. Install the filters in the correct order as shown. HEPA Filter Back Panel Active Carbon Deodorizing Filter Remove the plastic bag from each Install the Back Panel. filter. HEPA Filter Active Carbon Deodorizing Filter Click OPERATION START / STOP...
  • Page 9: Dehumidify Operation

    OPERATION DEHUMIDIFY OPERATION LAUNDRY OPERATION ♪ ♪ ♪ ♪ ♪ ♪ ♪ ♪ ♪ ♪ AUTO : AUTO : The humidity and the fan speed are automatically When you want to dry with less power controlled by the "temperature and humidity consumption, the Main Unit will repeat the sensor".
  • Page 10: Mold Control Operation

    OPERATION MOLD CONTROL OPERATION TIMER OPERATION This mode is used to suppress the mold through ON TIMER strong air flow with Plasmacluster Ion. The Main Unit automatically starts once the selected time passes. (with the Main Unit OFF) Front Display When turned ON, it firstly starts ventilation for 10 ♪...
  • Page 11: Swing Louver

    SWING LOUVER INTERNAL DRY OPERATION When you set the Internal Dry operation, the Main VERTICAL SWING Unit automatically operate the Air Flow mode for approximate 90 minutes after stopping. ♪ (with the Main Unit ON) ♪ ♪ ♪ ♪ CANCEL(OFF) DRY, DEODORIZE AIR PURIFY, DEHUMIDIFY more 3 sec.
  • Page 12: How To Change Various Setting

    OPERATION HOW TO CHANGE VARIOUS SETTING You can change the functions in the table "Type of setting". Turn off the Main Unit power. Type of setting ♪ Function Setting Auto Restart Cancellation If the Main Unit is unplugged or if there is a power failure, the Main Unit more 3 sec.
  • Page 13: How To Drain

    HOW TO DRAIN When you want to drain continuous When the Water Tank ♪ ♪・・・ is Full, the TANK FULL How to pipe the hose Indicator Light is blinking. Always have the tip slanted. Remove the Water Tank. Water Tank Under cold weather, do not put the hose into the water.
  • Page 14: Care And Maintenance

    CARE AND MAINTENANCE WATER TANK BACK PANEL / SENSOR (About once a week) (About once every 2 weeks) Remove the Tank Cover, and dispose of the water. Remove the dust gently with a Tank Cover cleaning tool such as a vacuum cleaner. ▶...
  • Page 15 FILTER INDICATOR FILTER REPLACEMENT The FILTER RESET Indicator light will turn on after LIFE OF FILTERS approximately 720 hours operating. (30 days × 24 hours Filter life varies depending on the room environment, =720 hours) usage conditions, and location of the Main Unit. RESET Lifespan of HEPA filter and Active Carbon Deodorizing Filter and replacement suggestions are...
  • Page 16 CARE AND MAINTENANCE When storing for a long period (not in use) Operate the INTERNAL DRY Dispose tank water and clean the Main OPERATION. ① Unit. Start operation. ♪ ② Select the Internal Dry Operation. Store in a dry place away from direct sunlight.
  • Page 17: Troubleshooting

    • Check whether the Main Unit is placed on a stable ERROR DISPLAY floor. • Check whether the Back Panel is not clogged. If error occurs repeatedly, contact the Sharp Service Center. Odor and smoke persists. • If the Water Tank is full, drain Air discharged from the Main Unit has an the water.
  • Page 18: Specifications

    SPECIFICATIONS Dehumidifying Specifications Model DW-J27FV / DW-J27FM DW-J20FM Power Supply 220V-240V/50Hz 30°C/80%RH 27 L/day 20 L/day ※ 1 Dehumidifying Capacity 26.7°C/60%RH 16 L/day 12.5 L/day ※ 2 Power Consumption 26.7°C/60%RH 345 W 260 W ※ 3 Standby Power 0.9 W 0.9 W ※...
  • Page 19 MEMO...
  • Page 20 MEMO...
  • Page 21 MEMO...
  • Page 22 SHARP CORPORATION OSAKA, JAPAN Printed in China TiNS-A016FBRZ 23F- 3...

This manual is also suitable for:

Plasmacluster dw-j27fmPlasmacluster dw-j20fm