Advertisement

Quick Links

AIR PURIFYING DEHUMIDIFIER
OPERATION MANUAL
Model
DW - E16FA
High - Density 7,000
*The number in this technology mark refers to the
approximate quantity of ions per cm
3
of air released from
the dehumidifier equipped with a high-concentration
Plasmacluster ion generating unit which was measured at
the center point (1.2 meter height above the floor) of high
concentration Plasmacluster 7,000 applicable floor area
room (temperature 20°C, humidity 50%) when the
dehumidifier was placed against the wall and runs in air
purifying mode with HIGH air flow.
Device of this mark is a trademark of Sharp Corporation.
Plasmacluster is a registered trademark or a
trademark of Sharp Corporation.
Do not use the product for business purpose.
CONTENTS
FEATURES
FAQs
●INSTALLATION LOCATION ●WHEN MOVING
●LAUNDRY DRYING
●DEHUMIDIFYING
●VERTICAL SWING LOUVER ●OFF TIMER
)
●CHILD LOCK ●NOTIFICATION SOUND OFF
●REAR PANEL ●WATER TANK
WHEN ODOR IS A CONCERN
●WHEN NOT USING FOR A LONG PERIOD
OF TIME
TROUBLESHOOTING
Thank you for purchasing this SHARP product.
Please read this Operation Manual carefully for proper usage.
Please be sure to read "SAFETY PRECAUTIONS" before use.
Keep this manual properly for future reference.
PAGE
E - 2
E - 3
E - 12
E - 13
E - 14
E - 14
E - 15
E - 18
E - 18
E - 19
E - 20
E - 22
E - 24
E - 25
E - 25
E - 26
E - 28

Advertisement

Table of Contents
loading

Summary of Contents for Sharp DW-E16FA-W

  • Page 1: Table Of Contents

    HIGH air flow. Device of this mark is a trademark of Sharp Corporation. Plasmacluster is a registered trademark or a Thank you for purchasing this SHARP product.
  • Page 2 FEATURES FAQs A powerful Dehumidifier with a High Concentration of The sound seems too loud? Plasmacluster Ions, a high performance HEPA filter ※1 There is a sound at the start of operation/during operation/when the unit stops. and a deodorizing active carbon filter for Room Air Purifying, This is the sound of compressor operation or refrigerant (coolant) circulation.
  • Page 3: Safety Precautionse

    SAFETY PRECAUTIONS WARNING To prevent any possible injury to persons or damage to property, be During Usage To prevent fire, electric shock or injury sure to follow the basic safety precautions, including the following: ● If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Page 4 Be sure to follow… CAUTION In order to prevent electric leakage and injury, and protect your household goods ● Always have plenty of room around the main unit. (Poor ventilation may cause over-heating, fire, and malfunction.) Power Plug, Power Cord ●...
  • Page 5: Parts Namee

    PARTS NAME MAIN UNIT AND CONTROL PANEL Control Panel OFF TIMER button E - 18 CHILD LOCK indicator light (green) E - 19 Sets the operation time for the OFF TIMER. Lighting...Child Lock is enabled ODOR Indicator Light (green, orange, red) OFF TIMER indicator light (green) Indicates the cleanness of the room by color.
  • Page 6: What You Need To Knowe

    WHAT YOU NEED TO KNOW DEHUMIDIFICATION MECHANISM AUTO OFF FUNCTION (LAUNDRY DRYING (HIGH/MED/LOW)/DEHUMIDIFYING) It is found that dew is formed on the surface of a cup holding cold water in the midsummer and water drop is The operation will stop automatically after 12 hours in case the unit has been forgotten to be turned off. attached to window glass of a room with heat supply.
  • Page 7: Before Use

    BEFORE USE WHEN USING FOR THE FIRST TIME INSTALLATION LOCATION Avoid places with direct sunlight. ● There might be some water left in the water tank from the factory product inspection. This is not a malfunction. ● May cause deformation or protection ●...
  • Page 8 NOTE HOW TO OPERATE Do not block the air outlet with clothes, etc. [Otherwise, over-heating, fire or malfunction may be caused] LAUNDRY DRYING DEHUMIDIFYING When drying laundry When you want to dehumidify, prevent dew formation on the ceiling, wall or window glass, or dry your tatami or closet. Select ●...
  • Page 9: How To Operate

    HOW TO OPERATE (Continued) DEODORIZING AIR PURIFYING When you want to deodorize your laundry Purifies the air in a room without dehumidifying Select Select AIR ● “LAUNDRY” will operate immediately after the ● “LAUNDRY” will operate immediately after the DEODORIZE. power plug is plugged in.
  • Page 10: Easy-To-Use Functions

    EASY-TO-USE FUNCTIONS VERTICAL SWING LOUVER PLASMACLUSTER ION ON/OFF ( When you want to change the louver angle Turn the Plasmacluster ion on/off During operation Select your desired During operation ● Do not forcibly move the louver with hands. "ON" "OFF" louver angle.
  • Page 11: How To Drain

    HOW TO DRAIN If there is a place you can drain nearby, continuous drainage is possible. WATER TANK CONTINUOUS DRAINAGE If the water tank becomes full (around 3.0L) during laundry drying or dehumidifying Unplug the How to pipe the hose operation, the operation will automatically stop power plug (Full tank stop device)
  • Page 12: Care And Maintenance

    WARNING CARE AND We recommend periodical cleaning for a long, clean and sanitary use! Diligent Always turn the operation “OFF” and unplug maintenance is also necessary for MAINTENANCE the power plug. releasing of steady and high concentration Plasmacluster ions. [Otherwise, electric shock or injury may be caused] WHAT YOU NEED TO KNOW If smell comes from the air outlet or it is hard to remove smell,...
  • Page 13: For Heavy Dust / E

    WARNING CARE AND We recommend periodical cleaning for a long, clean and sanitary use! Diligent Always turn the operation “OFF” and unplug maintenance is also necessary for MAINTENANCE the power plug. releasing of steady and high concentration Plasmacluster ions. (Continued) [Otherwise, electric shock or injury may be caused] REAR PANEL FOR HEAVY DUST / WHEN ODOR IS A CONCERN...
  • Page 14: Filter Replacement

    WARNING FILTER SPECIFICATIONS Always stop the operation and unplug the power plug before any REPLACEMENT replacement. [Otherwise, electric shock or injury may be caused] Dehumidifying Specifications Model DW-E16FA Power Supply 220V-240V/50Hz Once every five years ※ 30°C/80%RH 16L/day Dehumidifying Capacity ※1 8.8L/day 26.7°C/60%RH...
  • Page 15 TROUBLESHOOTING Please check one more time before calling for services. Problem Problem Solution Reference Solution Reference Page Page There is a sound at the start The room becomes hot ● Warm air will come out from the air outlet during laundry drying ●...
  • Page 16 ● When the main unit falls down while water enters the tank, pull out — (during dehumidifying or the power plug and consult the store where you purchased the laundry drying operation product or SHARP authorized service center. or while water enters the tank) E - 30 E - 31...

This manual is also suitable for:

Dw-e16fa

Table of Contents