Specification
Temperature Range
Airflow
Wet Bulb Temperature
Temperature Gradient
Temperature Shock
Relative Humidity
Humidity Gradient
Table 15
lists the storage and shipment temperature and humidity ranges
of the tape drive.
Specification
Dry Bulb Temperature
Wet Bulb Temperature
Temperature Gradient
Temperature Shock
Relative Humidity
Humidity Gradient
Chapter 10 Specifications
Temperature and Humidity Ranges
Value
10 ºC to 40 ºC (50 ºF to 104 ºF)
3.0 CFM (min.)
25 ºC (77 ºF)
11 ºC (19.8 ºF) per hour (across range)
10 ºC (18 ºF) over two minutes
20% to 80% non-condensing
10% per hour
Value
-
-
40 ºC to 66 ºC (
40 ºF to 150.8 ºF)
46 ºC (114.8 ºF)
20 ºC (36 ºF) per hour with 5º margin
(across the range)
15 ºC (27 ºF) with 5º margin (over two
minutes)
10% to 95% non-condensing
10% per hour