Firmware Update Via The Library Tape Drive Interface - Quantum DLT S4 User Manual

Quantum dlt s4: user guide
Hide thumbs Also See for DLT S4:
Table of Contents

Advertisement

Firmware Update via the Library Tape Drive Interface

DLT-S4 Product Manual
unloads and ejects it. SCSI status indicates that firmware has been
updated (06h, 3F, 01).
If the tape drive is mounted in a tape automation library,
Note:
the CUP/FUP cartridge rewinds to BOT and unbuckles in
preparation for unloading, but does not automatically
eject. Use the applicable library command to eject the
cartridge.
The DLT-S4 library tape drive interface enables you to update the
firmware with a new version, or image via media update.
Follow these steps.
Ensure that the tape drive contains no cartridge.
1
Send the
2
CODE UPDATE REQUEST
Send the library
3
ATTENTION
Status field of the returned General Status Packet to verify the tape
drive is in the Ready for Code Update (0x09) state.
Load the cartridge containing the new firmware into the tape drive.
4
Send the library
5
ATTENTION
Status field of the returned General Status Packet to verify the
cartridge is loading (0x07).
Send the library
6
ATTENTION
Status field of the returned General Status Packet to verify the
cartridge is in the CUP in Progress (0x0A) state.
It takes about 1 minute to enter the CUP in Progress (0x0A)
Note:
state.
Send the library
7
ATTENTION
Firmware Revision field to verify that the update completed
successfully.
Chapter 13 Using the Tape Drive
Firmware Update via the Library Tape Drive Interface
command.
command, then check the Tape Motion
command, then check the Tape Motion
command, then check the Tape Motion
command, then check the Policy
13
118