Quantum ACL 4/52 Supplementary Manual page 117

Automated tape library for dlt cartridges
Hide thumbs Also See for ACL 4/52:
Table of Contents

Advertisement

Sense
ASC
ASCQ
Key
5
25
00
5
26
00
5
26
02
6
28
01
6
29
00
6
2A
01
Introduction
Table is sorted by data in the ASC column
Message Name/Description
LOGICAL UNIT IS NOT SUPPORTED
Verify the logical unit field specified in the command
contains a legitimate logical unit number. Check cabling
to logical unit.
INVALID FIELD IN PARAMETER LIST
Verify Mode Select page fields.Verify that fields comply
with the command format described in the ACL 4/52
Software Interface Guide.
PARAMETER VALUE INVALID
Verify Mode Select page fields. Verify that fields comply
with the command format described in the ACL 4/52
Software Interface Guide.
This response will also be returned for commands
issued to the "Diagnostic" interface of the library if an
invalid parameter is sent.
IMPORT OR EXPORT ELEMENT ACCESSED
Load Port door has been closed.
POWER-ON, RESET OR BUS DEV. RESET OCCURRED
Informational message. If power on occurs, the host
user should assume the inventory may have been
corrupted, and should ask the library for that
information again.
MODE PERAMETERS CHANGED
Mode parameters may have changed due to another
host issuing a Mode Select command.
ACL 4/52 Software Interface Guide
Document 6211225-03
Interface
SCSI
SCSI
Both
Both
Both
SCSI
Version 3.0
A-3

Advertisement

Table of Contents
loading

Table of Contents