ESIE17-08
|
Part 5. Appendix

5.1.3. Remote controller

Mode No.
First Code No.
16 (26)
0
1
2
3
7
Page 110
R32 Sky-Air RZAG-M
Second Code No.
Description
01
Night time low
Disabled (Factory
noise operation
setting)
Automatic low
noise start and
stop time
EDP room setting
Disabled (Factory
setting)
Defrost starting
Standard (Factory
setting
setting)
Slow start for EDP
Normal start
applications
02
03
Automatic low
Capacity preced-
noise activation
ing setting (when
using KRP58
option)
22h00 ~ 06h00
EDP room setting
Defrost slow start-
Defrost quick
ing setting
starting setting
Slow start
04
05
Automatic low
noise + capacity
preceding
22h00 ~ 08h00
20h00 ~ 08h00
(Factory)
EDP room setting
+ no freeze up
15/11/18
5.1. Field setting
Details
Refer to
"Quiet
(Low Noise) Oper-
ation" on
page
113.
Refer to
"Quiet
(Low Noise) Oper-
ation" on
page
113.
Refer to
"Setting
for Low Humidity
Application" on
page
114.
Refer to
"Defrost
Operation" on
page
117.
|