INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING. THIS APPLIANCE WILL BECOME VERY HOT WHEN USED IN ACCORDANCE WITH THESE INSTRUCTIONS, HUNTER STOVES RECOMMEND THAT AN APPROVED GUARD IS USED TO PROTECT THE YOUNG, ELDERLY OR INFIRM FROM HARM.
ONOXIDE ETECTOR 7. Remove the cam bar by lifting the left-hand end Hunter Stoves recommend a Carbon Monoxide of it upwards until it clears the side casting. Pull Detector that conforms to the latest issue of BS EN the left-hand end towards the front of the stove 50292 is placed in the same room as the appliance.
Refit all the internal parts by following brick out of the Stove. the ‘removing internal component’ instructions in reverse order. APPLIANCE DIMENSIONS AVALON 4 Baffle/Throat Plate Lift the Baffle and slide to the right. When the left side of the Baffle clears the...
PRE-INSTALLATION REQUIREMENTS LEASE CHECK THE FOLLOWING Any existing chimney/flue system must be confirmed as suitable for this appliance as defined in Building Regulations Document J. It must be swept and inspected, by a competent person (see notes), to confirm that is structurally sound and free from cracks and obstructions.
2.3 M Air Supply beyond the boundary The room or space containing the Avalon 4, 5C, 5S and A full copy of Document J can be found here: 8S does not need a permanent, unobstructed air http://www.planningportal.gov.uk/uploads/br/BR_P opening.
Due consideration should be given to air requirements The stove can be recessed in a suitable sized fireplace for any other appliance in the same room or space. but a permanent free air gap of at least 150mm on top and 50mm at the sides (although we recommend Any air opening must be kept clear from blockage or 150mm for the sides and 50mm at the back of the obstruction.
Page 11
Hunter Stoves Group recommend that you carry out a Hunter Stoves Group also recommend that a CO alarm smoke draw test to check the soundness of the is fitted into the room where the appliance is located. chimney/flue system and seals:...
Operation with door left open It is essential that the stove has an adequate air Operation with the door open can cause excess smoke. The supply for combustion and ventilation. appliance must not be operated with the appliance door The primary and secondary air inlets must be kept left open except as directed in the instructions.
Page 13
Once you have a good fire established across the fuel bed from front to back. It should not be stacked grate bed, further fuel can be added as required and above the level of the rear firebrick as this the air controls set to the correct position. may result in damage to the stove.
Recommended Fuels This should be removed and cleaned at least once a Hunter Stoves Group recommend that only wood logs month to prevent any build-up of soot or fly ash that with a moisture content of less than 20% and...
Page 15
Painted Finish - Brush down the outer surface with a be ordered from the Hunter Stoves Group spares dry soft brush or microfiber cloth only and touch up range.
TROUBLESHOOTING ISSUE CAUSE RESOLUTION Problem starting the fire and Low flue draught Speak to your installer keeping it burning Wood with moisture content over 20% Ensure use of dry seasoned wood with less than 20% moisture content Unable to control fire High flue draught Speak to your installer Short burn time...
Page 17
ISSUE CAUSE RESOLUTION Creosote build-up in Wood with moisture content over Use dry seasoned wood (less chimney than 20% moisture content). Operate at a high temperature for short periods each time the appliance is used to avoid large build-ups of tars and creosotes. Tar coming from flue joints Appliance operated at continuous Operate at a high temperature...
INSTALLATION & COMMISSIONING CHECKLIST PURCHASE INFORMATION Dealer/Retailer Name Address Telephone Number Email Date Purchased INSTALLER INFORMATION Installer Name Address Telephone Number Email APPLIANCE INFORMATION Date Installed Appliance Stock Code Appliance Description Serial Number COMMISSIONING CHECK (Complete & Sign) Does the chimney/flue system meet the appropriate standard? Has the chimney/flue system been swept and passed the soundness test? Has this appliance passed the flue draught test? Please write down the flue draught reading:...
SERVICE RECORDS Service Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company/ Servicing Company/ Engineer Engineer Signature Signature Service Service Date of Service Date of Service Date of next Service Date of next Service Servicing Company/ Servicing Company/ Engineer...
This is needed in the event of a claim during the warranty period. Only genuine Hunter Stoves spare parts or consumables can be used in the servicing and maintenance of the appliance during any standard or extended warranty period. These can be sourced from your authorised supplier directly or through our website spares portal.
Page 26
Cost associated with the removal and re-installation of an appliance subject to a warranty claim. Hunter Stoves Group total liability will only extend to the total purchase price paid for the goods in any warranty claim. Hunter Stoves Group reserve the right to replace, repair or refund to value of goods purchased.
Need help?
Do you have a question about the AVALON 4 and is the answer not in the manual?
Questions and answers