Summary of Contents for Fluke 972A

  • Page 1 972A/972B Temperature Humidity Meter Users Manual 4/2023 (English) © 2023 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ..............................1 How to Contact Fluke ..........................1 Safety Information ..........................1 Product Familiarization ..........................2 Standard Packaging..........................2 Model Comparison Table ........................3 Operation Features ..........................3 Components and Controls ......................3 Screen ............................7 Use the Meter ...............................
  • Page 5: Introduction

    Introduction The 972A/972B Temperature Humidity Meter (the "Product" or "Meter") is a battery-powered temperature and relative humidity measurement meter. The Meter features: • Temperature and humidity measurement • Optional built-in and external sensors. • 99 sets of stored data (972B only) •...
  • Page 6: Product Familiarization

    If you need to reship the Product, please use the original package. If the original package is not available, a new package can be ordered from Fluke according to the Product’s model. list the standard items that comes with the Product.
  • Page 7: Model Comparison Table

    Temperature Humidity Meter Product Familiarization Table 1. Standard equipment Item Description Part Number 972A 972B The Temperature Humidity Meter External temperature/humidity sensor 972 ES AAA type battery (installed) Soft case Documentation, including a Quick 5577512 Reference Guide and a Safety...
  • Page 8: Screen

    972A/972B Users Manual Figure 2. Product Features Table 3. Product Features Item Description External sensor External temperature/humidity sensor (standard with 972B). Use External Sensor for details. Built-in sensor Built-in temperature and humidity sensors. LCD display Screen for details. Power button Turn on or off the Meter.
  • Page 9 Save Measurement Data for details. Temperature / Humidity button Temperature/Humidity switch button (972A only) Wet bulb/dew The Meter shows the current measured temperature and humidity by default point button after it is powered on, and each time the button is pressed briefly, the Meter...
  • Page 10 972A/972B Users Manual Item Description MAX/MIN button When this button is pushed during measurement, the MAX/MIN temperature symbol shows on the Meter's screen, indicating that the Meter is in the MAX/MIN/AVE calculation mode. The Meter starts calculating the MAX/MIN temperature and humidity values at the same time.
  • Page 11: Screen

    Temperature Humidity Meter Product Familiarization Item Description Batteries 2 AAA batteries, installed Protective cover The lanyard can effectively prevent losing the interface protective cover. lanyard One end of the lanyard is tied to a fixed point on the protective cover, and the other end with a small clip that snaps into a slot inside the battery compartment is threaded through a small groove in the battery compartment cover.
  • Page 12 972A/972B Users Manual Item Description Memory When the symbol flashes on the screen, it indicates that the Meter is in Recall mode. Recall Historical Data for details. Storage location number The storage locations are numbered 01 to 99. In Measurement mode, this number indicates the storage location to be used.
  • Page 13: Use The Meter

    Temperature Humidity Meter Use the Meter Use the Meter Turn On/Off the Meter Use the Power button on the front panel to turn the Meter on and off. • Power on: Push and hold for 2 seconds, release the button when the screen lights up. •...
  • Page 14: Min/Max/Ave Values

    972A/972B Users Manual Figure 5. Wet bulb and dew point temperature Min/Max/Ave Values Each time you push during measurement, the Meter’s screen will show the MIN/MAX temperature symbol and cycle through these screens: • shows on the screen, as shown on the left in...
  • Page 15: Recall Historical Data

    Temperature Humidity Meter Use the Meter Increase by 1 Figure 7. Save Measurement Data Note If all 99 storage locations already have data saved, the system automatically overwrites the data stored in location 01 and continues to increase the storage location number.
  • Page 16: Clear Historical Data

    972A/972B Users Manual Clear Historical Data To clear all data saved in the Meter, push and hold simultaneously for at least 5 seconds until the storage location number is 01.  Caution This procedure will erase all the data saved in the Meter and cannot be recovered, so please be careful.
  • Page 17: Maintenance

    Temperature Humidity Meter Maintenance Maintenance There are no parts requiring for users to repair and maintain inside the Product, and no special maintenance is needed, only daily cleaning is required. Clean the Case Clean the case with a damp cloth and a weak soap solution. ...
  • Page 18: Product Disposal

    972A/972B Users Manual Product Disposal Dispose of the Product in a professional and environmentally appropriate manner: • Delete personal data on the Product before disposal. • Remove batteries that are not integrated into the electrical system before disposal and dispose of batteries separately.
  • Page 19: Specifications

    Temperature Humidity Meter Specifications Specifications General Specifications 972A 972B 972 ES Temperature Operating -30 °C to 70 °C -40 °C to 70 °C Storage -30 °C to 70 °C, <80 % RH (without battery) -40 °C to 70 °C, <80 %RH...
  • Page 20: Detailed Specifications

    972A/972B Users Manual Detailed Specifications 972A 972B 972 ES Sensor Type Built-in Built-in + External External -30.0 °C to 70.0 °C -30.0 °C to 70.0 °C (built-in -40.0 °C to 100 °C Temperature Measurement sensor) Range -40.0 °C to 100 °C...