Figure 9. Network Module Installation - ADTRAN 17004660F1/F3 Hardware Installation Manual

Table of Contents

Advertisement

Unit Installation
Electronic modules can be damaged by static electrical discharge. Before
handling modules, put on an antistatic discharge wrist strap to prevent damage
to electrical components. Place modules in antistatic packing material when
transporting or storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
Always remove power from the unit prior to removing or installing a module.
Improper installation could result in damage to the modules.
Step
1
Remove power from the unit.
2
Use a screwdriver to remove the cover plate from the option slot in the NetVanta base unit.
3
Slide the option module into the option slot until the module is firmly seated against the chassis
(see
Figure
9).
4
Secure the screws at both edges of the module using a screwdriver.
5
Connect the cables to the associated device(s).
6
Restore power to the unit.
NetVanta 4660
STAT
FAN
1 PPS
GIG 0/1
GIG 0/2
OUT
CONSOLE
48VDC
Your NetVanta unit is now ready to be configured and connected to the network. For information on
configuration for a specific application, refer to the configuration guides provided online on
Support Forum
For details on the CLI, refer to the
documents are also available online on
30
Instructions for Installing the Network Modules
GIG 0/3
GIG 0/4
GIG 0/5

Figure 9. Network Module Installation