INSTALLATION

The appliance must be installed by a
qualified technician and according to
the regulations in force.
Appliance factory set for: natural gas
G20 at a pressure of 20 mbar.

Gas connection

See General safety instructions.
Connection to the gas mains can be made using
a continuous wall steel hose in compliance with
the guidelines established by the standards in
force. To use other types of gas, see the chapter
"Adaptation to different types of gas". The
appliance's gas connector has a ½" external
thread (ISO 228-1).
Connection with a steel hose
Make the connection to the gas mains using a
continuous wall steel hose whose specifications
comply with the applicable standard.
1
2
3
Carefully screw the connector 3 to the gas
connector 1 of the appliance, placing the seal 2
between them.
91477A898/A
• Make sure that the food has not spilled out
of the pan and use a larger cooking vessel,
if needed.
The fuses blow or the circuit breaker of the
residential electrical system trips repeatedly.
• Call Technical Support or an electrician.
Connection with a steel hose with conical
fitting
Make the connection to the gas mains using a
continuous wall steel hose whose specifications
comply with the applicable standard.
1
2
3
4
Carefully screw the hose connector 3 to the
appliance's gas connector 1 (½" thread ISO
228-1), placing the seal 2, provided, between
them. Apply insulating material to the thread of
connector 3 and then screw the steel hose 4
onto the connector 3.
Connection to LPG
Use a pressure regulator and make the
connection on the gas cylinder following the
guidelines set out in the standards in force.
The supply pressure must comply with the values
indicated in the "Burner and nozzle
characteristics table".
Room ventilation
The appliance should be installed in rooms that
have a permanent air supply in accordance
INSTALLATION - 31