THIS IS A CLASS 3 BUILT IN HOB. INSTRUCTIONS FOR THE USER: these contain user advice, the description of the controls and the correct procedures for cleaning and maintenance of the appliance. INSTRUCTIONS FOR THE INSTALLER: these are intended for the qualified technician who must install the appliance, set it functioning and carry out an inspection test.
General instructions 1. INSTRUCTIONS FOR USE This manual is an integral part of the appliance. It must be kept in its entirety and in an accessible place for the whole working life of the appliance. We recommend reading this manual and all information it contains carefully before using the appliance.
General instructions Never place saucepans with bases which are not perfectly flat and smooth on the hob. Never use cookware which extends beyond the external perimeter of the hob.
Do not remove the plate on the casing for any reason. Before connecting the appliance, ensure that it is set to the type of gas that it will be supplied with, checking the label applied under the casing.
Page 5
Do not allow unsupervised children to perform cleaning or maintenance operations. Do not let children go near the appliance when it is in operation or play with it at any time. Do not insert pointed metal objects (cutlery or utensils) into the slots in the appliance.
You can obtain the addresses of collection, recycling and disposal centres from your retailer or from the competent local organisations. Do not discard the packaging or any part of it, or leave it unattended. It can constitute a suffocation hazard for children, especially the plastic bags.
Rapid Burner (R) Double crown Burner (UR2) KNOB DESCRIPTION To light the flame, press the knob and, at the same time, turn it anticlockwise to the maximum flame symbol To adjust the flame, turn the knob to the zone between the...
For the UR2 double burner, place and fit perfectly the burner caps G and E on the flame-spreader crowns F and D. The latter have to be placed on support C and then fitted in the base B. The supplied pan stand H is for use with woks. Lighting the hob burners The burner controlled by each knob is shown next to the knob.
Page 9
For better burner efficiency and to minimise gas consumption, use pans with a flat, smooth base and a lid that have a suitable size for the burner, thus preventing the flames reaching the sides of the pan (see point “5.3 Cookware diameters”).
To clean and preserve stainless steel surfaces, use only specific products that do not contain abrasives or chlorine-based acids. How to use: pour the product onto a damp cloth and wipe the surface, rinse thoroughly and dry with a soft cloth or chamois leather.
Page 11
For easier cleaning they can be removed by pulling them upwards. Dry thoroughly after cleaning. Do not use aggressive products containing alcohol or products for cleaning steel and glass when cleaning the knobs, as these products could cause permanent damage.
The seal must be placed at a distance of 3-4 mm from the external perimeter of the hole made in the counter top. Do not fix the hob using silicone as this would make it impossible to remove the hob, if necessary, without damaging it.
Page 13
Keep a minimum distance of 10 mm between the bottom of the appliance and the panel surface (as shown in the figure). If the appliance is instead on an oven installed under the hob, there is no need to install a separating shelf. The oven must be equipped with a cooling fan.
Page 14
The air vents, protected by grills, must be the right size to comply with current regulations and positioned so that no part of them is obstructed, not even partially.
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. For supplying it with other types of gas, see chapter "9. ADAPTATION TO DIFFERENT TYPES OF GAS".
Page 16
Connection with a rigid copper hose The connection to the gas supply network must be made in such a way that it does not cause stresses of any type on the appliance. Carefully screw the adapter unit 3 with double cone to the gas connector 1 of the appliance, placing the supplied seal 2 between them.
Before carrying out the following operations, disconnect the appliance from the power supply. The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In case of operation with other types of gas, the burner nozzles must be changed and the minimum flame adjusted on the gas taps.
Instructions for the installer Burner and nozzle characteristics table Rated heating Burner capacity Natural gas – G20 20 mbar (kW) Nozzle diameter Reduced capacity 1/100 mm Auxiliary (1) 1.05 Rapid (2) 2.50 INT Double crown (3) 1.00 EXT Double crown (3) 4.20...
Page 19
The bypass diameters for each individual burner are shown in table “9.2 Burner and nozzle characteristics table”. After adjustment with a gas other than the preset one, replace the label on the bottom of the appliance with the label corresponding to the new gas. This label can be obtained from the nearest Authorised Service Centre or supplied where envisaged.
Do not remove this plate for any reason. The plug at the end of the supply cable and the wall socket must be of the same type and must conform to the applicable legislation on electrical installations.