Setting The Minimum Gas Flow; Checking Functions After The Conversion; Conversion To Natural Gas - Bosch HDS8645U Installation Instructions Manual

Free-standing range
Hide thumbs Also See for HDS8645U:
Table of Contents

Advertisement

Available languages

Available languages

en-us Conversion to Propane gas (LPG)
Dual-flame burner
Place the burner cup B onto the burner C and place the
4.
burner cover A onto the burner cup B.
Refit the grates.
5.
4.5 Setting the minimum gas flow
Remove the control knob and knob ring.
1.
Turn the inner setting screw clockwise gently until it bot-
2.
toms out.
In case of conversion from propane gas to natural
gas, turn out all bypass nozzles for 1/2 turn.
Small burner/large burner
26
Dual-flame burner
Replace the control knobs.
3.
Light each burner individually and check for flame sta-
4.
bility on low setting.
If required, loosen the setting screw to increase the gas
5.
flow.
Ensure that the flame does not go out when the gas
6.
flow is quickly changed between maximum and mini-
mum, and vice versa. The optimum setting is achieved
when the height of the small flame is approx. 1/8" (3 to
4 mm).
Refit the control knob and knob ring for the gas burner.
7.
Repeat steps 2 to 8 until all of the gas burners have
8.
been set.
Connect the appliance to the power supply.
9.
4.6 Checking functions after the conversion
The flames must not go out when switching over swiftly
from the high to the low setting.
Note: Stick the adhesive label included with the nozzle set
near the rating plate of the appliance to document the
changeover to a different gas type.
Test for Gas Leaks
After the conversion it is important to test for gas leaks.
→  Page 22
4.7 Conversion to natural gas
This appliance is shipped from the factory for use with nat-
ural gas.
If the appliance has been converted to propane gas be-
fore, you have to convert it to natural gas again.
Check the orifices for the right nozzles and, if required, re-
place them. See "Replacing the main control nozzles".
Adjust the minimum gas flow. See "Setting the minimum
gas flow". The optimum setting is achieved when the
height of the small flame is approx. 1/8" (3 to 4 mm).
Set the pressure regulator for natural gas. Turn the spring
plate the other way around as shown in "Setting the pres-
sure regulator for propane gas".
Save the orifices removed from the appliance for future
use.

Advertisement