Cmc iii analogue differential pressure sensor (16 pages)
Summary of Contents for Rittal DK 7030.140
Page 1
CMC III Analoger Luftstromsensor CMC III Analogue Air Flow Sensor Détecteur de débit d'air analogique CMC III DK 7030.140 Installations- und Kurz-Bedienungsanleitung Installation and Short User Guide Notice d'installation et d'utilisation succincte...
Page 2
Abb./Fig./Fig. 2: Montage Adapter / Mounting the adaptor / Montage de l'adaptateur Abb./Fig./Fig. 3: Montage Schrankprofil / Mounting the enclosure section / Montage du profilé d'armoire Rittal CMC III Analoger Luftstromssensor / Analogue Air Flow Sensor / Détecteur de débit d’air analogique...
Page 3
Abb./Fig./Fig. 4: Montage Systemchassis / Mounting the punched section with mounting flange / Montage du châssis M4x10 = 0,5 Nm Abb./Fig./Fig. 5: Montage Hutschiene / Mounting the top hat rail / Montage du rail oméga Rittal CMC III Analoger Luftstromssensor / Analogue Air Flow Sensor / Détecteur de débit d’air analogique...
Page 4
Abb./Fig./Fig. 6: Montage Sensor / Mounting the sensor / Montage de la sonde Abb./Fig./Fig. 7: Anzeigeelemente, Stecker und Anschlüsse / Display elements, plugs and connectors / Organes de signalisation, fiches et raccordements Rittal CMC III Analoger Luftstromssensor / Analogue Air Flow Sensor / Détecteur de débit d’air analogique...
Informationen zur Montage, Installation und Funktion des CMC III Analogen Luft- stromsensors (nachfolgend Luftstromsensor genannt). Mitgeltende Unterlagen Montage-, Installations- und Bedienungsanleitung CMC III Analoger Luftstromsensor. Sie ist unter www.rittal.de verfügbar und enthält die vollständigen anwendungsrelevanten Informationen und technischen Daten zum Luftstromsensor in Hinblick auf: – Weitere Montagemöglichkeiten – Funktionen –...
Drücken Sie die „C“-Taste an der CMC III PU (ein erster Signalton ertönt) und halten Sie sie für ca. 3 Sekunden gedrückt, bis ein zweiter Signalton ertönt. Anzeige der Statusänderung an den CAN-Bus LEDs: – Dauerlicht grüne LEDs: Status CAN-Bus „OK“. Rittal CMC III Analoger Luftstromssensor...
Page 7
– SetPtLowAlarm: unterer Alarmgrenzwert [%] – Hysteresis: Verzögerung der Statusmeldung [%] – Status: Aktueller Status des Luftstromsensors unter Berücksichtigung der Hysterese Eventuell notwendige Softwareupdates: siehe www.rittal.de oder Anfrage bei Rittal Service (vgl. Abschnitt 6). Service Zu technischen Fragen wenden Sie sich bitte an: Tel.: +49(0)2772 505-9052...
CMC III Analogue Air Flow Sensor (subsequently called air flow sensor). Associated documents CMC III Analogue Air Flow Sensor assembly and operating instructions. It is available at www.rittal.com and contains the complete application-relevant information and techni- cal data for the air flow sensor with regard to: – Further assembly possibilities –...
Press the "C" key on the CMC III PU (a first audio signal is issued) and keep it pressed for approx. 3 seconds until a second audio signal is issued. Display of the status change on the CAN bus LEDs: – Green LEDs light continuously: CAN bus status "OK". Rittal CMC III Analogue Air Flow Sensor...
Page 10
– SetPtLowAlarm: Lower alarm limit value [%] – Hysteresis: Status message delay [%] – Status: Current status of the air flow sensor taking account of the hysteresis To determine whether any software updates are required: see www.rittal.com or contact Rittal Service (see section 6). Service For technical questions, please contact: Tel.: +49(0)2772 505-9052...
Notice de montage, d'installation et d'utilisation du détecteur de débit d’air CMC III. Elle est disponible sous www.rittal.com et contient les informations complètes relatives à la mise en œuvre et les caractéristiques techniques du détecteur de débit d’air dans les domaines suivants : –...
– La LED multiple du détecteur de débit d’air clignote en bleu de manière continue. Actionner la touche «C» de l'UC CMC III (un premier signal sonore retentit) et la maintenir actionnée pendant env. 3 secondes jusqu'à ce qu'un deuxième signal sonore retentisse. Détecteur de débit d’air analogique CMC III Rittal...
Page 13
– Hysteresis : temporisation du message d'état [%] – Status : état actuel du détecteur de débit d’air du point de vue de l'hystérésis Si des mises à jour de logiciel sont éventuellement nécessaires : voir www.rittal.com ou sur demande au service Rittal (voir paragraphe 6).
Page 14
Pour des questions techniques, veuillez vous adresser à : Tél. : +49(0)2772 505-9052 E-mail : info@rittal.de Site Internet : www.rittal.com Pour des réclamations ou un service, veuillez vous adresser à : Tél. : +49(0)2772 505-1855 E-mail : service@rittal.de Détecteur de débit d’air analogique CMC III Rittal...
Page 15
Notes/Notizen Rittal CMC III Analoger Luftstromssensor / Analogue Air Flow Sensor / Détecteur de débit d’air analogique...
Page 16
◾ Climate Control ◾ IT Infrastructure ◾ Software & Services You can find the contact details of all Rittal companies throughout the world here. www.rittal.com/contact RITTAL GmbH & Co. KG Auf dem Stuetzelberg · 35745 Herborn · Germany Phone +49 2772 505-0...