3. OPERATION

3.1 On/Off Switch
When switched to "on" with the push button, the product is fully functional. The inverter will
come into operation and the LED "inverter" will light up. By pushing the push button
subsequently, within a short period of time, the inverter toggles between "on", "ECO" and "off".
Apart from the pushbutton; the inverter can also be switched on (normal or ECO) and off with
Bluetooth on a mobile device running iOS or Android and the Victron Connect app. However
when switched off via Bluetooth or the push button; the unit cannot be switched on and off
again via the wired VE.Direct port.
3.2 Remote control
Remote control is possible with a simple on/off switch or with a Phoenix Inverter Control
panel. A switch for remote control (on/off) can be connected to a two pole connector. The
switch can also be connected between battery plus and the left hand contact of the two pole
connector (marked "H"; see appendix A) or between battery minus and the right hand contact
of the two pole connector (marked "L"; see appendix A).
For safety purposes, this product can be turned off completely (i.e. the inverter
cannot be switched on via the push button or Bluetooth) by removing the remote
connector and its default installed wire bridge (or swtich off the remote on/off
switch if installed). The user can then be certain that the inverter cannot be
switched on accidently via Bluetooth by an unexpected other user.
3.3 LED definitions
Green LED
●●●●●●●●
●●------
single pulse
●-●-----
double pulse
--------
●-●-●-●-
4
Status
Solid on Inverter on
ECO mode
Slow
Off and waiting Inverter did shut down because of a protection. The
Fast
Inverter off
Off
Off and
Fast
Trouble shooting
Red LED Off
status OK
Red LED On or blinking:
The Inverter is still on, but will shut down when the
condition gets worse. See red LED table for warning
reason
If the inverter keeps switching on and off while there is a
load connected, the load may be too small compared to the
actual ECO mode settings. Increase the load or change
ECO mode settings. (minimum ECO mode setting: 15W)
inverter will restart automatically as soon as all alarm
conditions are cleared. See red LED state for the shutdown
reason.
Red LED Off
Check Remote on/off connector.
Check DC cable connections and fuses.
Check operational mode by pushing push button one time.
Red LED On or blinking
The inverter did shut down because of a protection. It will
no longer automatically restart. The red LED indicates the
reason for shutdown. Remove the cause and then restart
the inverter by switching it Off, and then back On.
-●-●-●-●
Red LED Blinking (
)