Calendar Override (760 On-Demand Controller Only); Amount Of Brine Used Per Regeneration - Pentair Autotrol 255 Logix 740-760 Installer Manual

Table of Contents

Advertisement

6.3.7. Calendar override (760 on-demand controller only)

Set number of days for calendar override on-demand controller.
A
Press
.
→ Number of days flashes.
B
Adjust displayed number with
→ Default time for calendar override: 0 day.
→ Days can be adjusted from ½ (.5) to 99 days.
C
Press
to validate the selection and advance to the next
parameter using

6.3.8. Amount of brine used per regeneration

Set desired brine amount. 3 salt settings are available on 740 and 760 controllers:
S – Standard Salt – 120 grams/liter of resin;
H – High Salt – 200 grams/liter of resin;
L – Low Salt – 45 grams/liter of resin.
A
Press
.
→ Setting flashes.
B
Adjust displayed settings with
→ Default setting is "S" standard salting.
C
Press
to validate the selection and advance to the next
parameter using
Filter Backwash Time (Filter Mode Only)
If the system is set up as a filter, the brine amount is unnecessary. The controller deactivates the brine
amount setting, and changes to an adjustable backwash time in minutes.
A
Press
.
→ Time flashes.
B
Adjust displayed time with
→ Default time: 14 minutes.
→ The controller can be adjusted from 0 to 99 minutes for backwash.
C
Press
to validate the selection and advance to the next parameter using
Ref. MKT-IM-001 / C - 08.10.2019
and
.
or
.
and
.
or
.
and
.
Installer Manual 255-LOGIX 740-760 - Programming
or
.
39 / 76

Advertisement