ERROR CODE
A10
A11
A20
A30
A40
A41
A42
A60
A70
A80
A90
A91
A58
A59
CFS
SFS
FIL
>3.0 bar
3. WHAT IF...
3.1

WHAT IF I SUSPECT A GAS LEAK

If you suspect a gas leak, turn off the gas supply at the gas
meter and contact your installer or local gas supplier. If you
require further advice please contact your nearest Vokèra office.
3.2
WHAT IF I HAVE FREQUENTLY TO
TOP-UP THE SYSTEM
If the system regularly requires topping-up, it may be indicative
of a leak. Please contact your installer and ask him to inspect
the system.
3.3
WHAT IF THE APPLIANCE IS DUE ITS
ANNUAL SERVICE
Advice for tenants only
Your landlord should arrange for servicing.
Advice for homeowners
Please contact Vokèra Customer Service (0844 3910999 (UK)
or 056 7755057 (ROI) if you would prefer a Vokèra service
engineer or agent to service your appliance. Alternatively your
local GAS SAFE registered engineer may be able to service
the appliance for you.
3.4
WHAT IF I NEED TO CALL AN
ENGINEER
If you think your boiler may have developed a fault, please contact
your installer or Vokèra Customer Services (0844 3910999 (UK)
or 056 7755057 (ROI) have all your details to hand including
full address and postcode, relevant contact numbers, and your
completed appliance log book.
8
ERROR MESSAGE
Flame lockout
Condensate drain obstructed
Flue gas exhaust/air suction obstructed
Extraneous fl ame
Limit thermostat
Fan fault
Fill the system
Fill the system
Pressure transducer fault
DHW probe fault
Flow sensor fault
Flow sensor overtemperature
Flow/return sensor diff erential
Return probe fault
Return probe overtemperature
Return-fl ow sensor diff erential
Flue gas probe fault
Clean primary heat exchanger
Low power supply voltage
High power supply voltage
Call Service
Stop for Service
Low pressure - check system
High pressure - check system
DESCRIPTION OF TYPE OF ALARM
defi nitive
transitional
defi nitive
defi nitive
defi nitive
transitional
defi nitive
transitional
transitional
defi nitive
defi nitive
transitional
defi nitive
defi nitive
transitional
transitional
transitional
transitional
signal
defi nitive
signal
signal

Hide quick links: